Error description

  • OMEGAMON DB2 (OMPE) will take an 0C4 abend at offset 1CEBA in
    load module FPEVSERV. This is at offset 2D2 into mod FPEVSAD3.
    Monitoring of that DB2 subsystem will terminate but the task
    will continue to run and monitor other DB2 subsystems.
    
    In the course of processing IFCID002, the length of multiple
    records that complete a single statistics interval may exceed
    the length of the internal work area.
    
    Additional Keywords:
    IFCID0002 IFCID02 IFCID2 IFCID002 statistics ifcid bufferpool
    group buffer pool gbp bp
    

Local fix

  • apply ptf when available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: The monitoring PE Server subtask load   *
    *                      module FPEVSERV abends with system      *
    *                      completion code 0C4.                    *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    When statistics performance data are requested from PE Server
    to monitor a DB2 subsystem, PE Server merges the received data
    for IFCID 2. The resulting data structure exceeds the size of
    an internal buffer and causes Abend 0C4 when it is written to
    this buffer.
    
    PROBLEM CONCLUSION:
    The code has been corrected accordingly to allocate an internal
    buffer which fits the size of the intermediate data structure.
    
    KEYWORDS:
    FPEVSERV ABEND 0C4
    

Problem conclusion

  • The code has been corrected accordingly to allocate an internal
    buffer which fits the size of the intermediate data structure.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI58304

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-01

  • Closed date

    2016-03-15

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI36215 UI36216

Modules/Macros

  • DGOVCRDB DGOVDSS  DGOVMSTR DGOVSADK DGOVSCLR DGOVSCNT DGOVSCON
    DGOVSDTS DGOVSLOC DGOVSORT FPEMEXA0 FPEVDB2F FPEVDB2I FPEVDB27
    FPEVNTM  FPEVNT00 FPEVRTM  FPEVSAD3 FPEVXCMM FPEVZMAI
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R520 PSY UI36215

       UP16/03/15 P F603

  • R530 PSY UI36216

       UP16/03/15 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 February 2017