Error description
OMEGAMON DB2 (OMPE) will take an 0C4 abend at offset 1CEBA in load module FPEVSERV. This is at offset 2D2 into mod FPEVSAD3. Monitoring of that DB2 subsystem will terminate but the task will continue to run and monitor other DB2 subsystems. In the course of processing IFCID002, the length of multiple records that complete a single statistics interval may exceed the length of the internal work area. Additional Keywords: IFCID0002 IFCID02 IFCID2 IFCID002 statistics ifcid bufferpool group buffer pool gbp bp
Local fix
apply ptf when available
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - PE Server subtask * **************************************************************** * PROBLEM DESCRIPTION: The monitoring PE Server subtask load * * module FPEVSERV abends with system * * completion code 0C4. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: When statistics performance data are requested from PE Server to monitor a DB2 subsystem, PE Server merges the received data for IFCID 2. The resulting data structure exceeds the size of an internal buffer and causes Abend 0C4 when it is written to this buffer. PROBLEM CONCLUSION: The code has been corrected accordingly to allocate an internal buffer which fits the size of the intermediate data structure. KEYWORDS: FPEVSERV ABEND 0C4
Problem conclusion
The code has been corrected accordingly to allocate an internal buffer which fits the size of the intermediate data structure.
Temporary fix
Comments
APAR Information
APAR number
PI58304
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-01
Closed date
2016-03-15
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36215 UI36216
Modules/Macros
DGOVCRDB DGOVDSS DGOVMSTR DGOVSADK DGOVSCLR DGOVSCNT DGOVSCON DGOVSDTS DGOVSLOC DGOVSORT FPEMEXA0 FPEVDB2F FPEVDB2I FPEVDB27 FPEVNTM FPEVNT00 FPEVRTM FPEVSAD3 FPEVXCMM FPEVZMAI
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 February 2017