Fixes are available
Rational ClearCase Fix Pack 6 (9.0.0.6) for 9.0
Rational ClearCase Fix Pack 2 (9.0.1.2) for 9.0.1
Rational ClearCase Fix Pack 16 (8.0.1.16) for 8.0.1
Rational ClearCase Fix Pack 17 (8.0.1.17) for 8.0.1
Rational ClearCase Fix Pack 3 (9.0.1.3) for 9.0.1
Rational ClearCase Fix Pack 4 (9.0.1.4) for 9.0.1
Rational ClearCase Fix Pack 18 (8.0.1.18) for 8.0.1
Rational ClearCase Fix Pack 5 (9.0.1.5) for 9.0.1
Rational ClearCase Fix Pack 19 (8.0.1.19) for 8.0.1
Rational ClearCase Fix Pack 6 (9.0.1.6) for 9.0.1
Rational ClearCase Fix Pack 20 (8.0.1.20) for 8.0.1
Rational ClearCase Fix Pack 7 (9.0.1.7) for 9.0.1
Rational ClearCase Fix Pack 21 (8.0.1.21) for 8.0.1
Rational ClearCase Fix Pack 8 (9.0.1.8) for 9.0.1
Rational ClearCase Fix Pack 22 (8.0.1.22) for 8.0.1
Rational ClearCase Fix Pack 9 (9.0.1.9) for 9.0.1
Rational ClearCase Fix Pack 23 (8.0.1.23) for 8.0.1
Rational ClearCase Fix Pack 10 (9.0.1.10) for 9.0.1
Rational ClearCase Fix Pack 24 (8.0.1.24) for 8.0.1
Rational ClearCase Fix Pack 11 (9.0.1.11) for 9.0.1
Rational ClearCase Fix Pack 25 (8.0.1.25) for 8.0.1
Rational ClearCase Fix Pack 12 (9.0.1.12) for 9.0.1
Rational ClearCase Fix Pack 13 (9.0.1.13) for 9.0.1
APAR status
Closed as program error.
Error description
When working in an IBM Rational ClearCase dynamic view, you may experience a Microsoft STOP error (BSOD) of NTFS_FILE_SYSTEM (24), when using Visual Studio 2015 with Intel Inspector XE v2016. WORKAROUND: Use snapshot views
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of ClearCase dynamic views on Microsoft Windows * **************************************************************** * PROBLEM DESCRIPTION: * * When creating a new ClearCase dynamic view, the command * * syntax requires specification of a storage path for the view * * repository. If the repository is on a local device, but the * * cleartool command line options for specifying storage * * locations using the <-host, -hpath, -gpath> triplet is used * * on Microsoft Windows, the storage path appears to be a * * remote filesystem. This may cause some I/O operations to * * traverse a pathname in such a way which causes a Microsoft * * STOP error (BSOD). * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The cleartool mkview command has been modified to prevent this incorrect storage path specification in ClearCase 8.0.1.16, 9.0.0.6, and 9.0.1.2.
Temporary fix
Comments
APAR Information
APAR number
PI57999
Reported component name
CC&CC MSITE WIN
Reported component ID
5724G3300
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-24
Closed date
2017-12-18
Last modified date
2017-12-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CC&CC MSITE WIN
Fixed component ID
5724G3300
Applicable component levels
R801 PSY
UP
R900 PSY
UP
R901 PSY
UP
Document Information
Modified date:
12 January 2022