A fix is available
APAR status
Closed as program error.
Error description
In E3270 UI session, when a user selects EDM Tab and F8 to page down this error occur: OB0910: Program Check - Recovery Successful-A27F9D38
Local fix
Copy KDPEDMB member from RKANWENU dataset to UKANENU and comment out or delete MODE=SILENT statement.
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Enhanced 3270 UI * **************************************************************** * PROBLEM DESCRIPTION: OB0910: PROGRAM CHECK - RECOVERY * * SUCCESSFUL-A27F9D38 AFTER SELECTING * * EDM TAB FROM TOM * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Some of the syntax in Enhanced 3270 workspace KDPEDMB causes TOM to abend 0C4. PROBLEM CONCLUSION: Changed syntax in workspace KDPEDMB to prevent abend 0C4. KEYWORDS: WORKSPACE KDPEDMB OB0910: PROGRAM CHECK
Problem conclusion
Changed syntax in workspace KDPEDMB to prevent abend 0C4.
Temporary fix
Comments
APAR Information
APAR number
PI57892
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-24
Closed date
2016-04-12
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36951
Modules/Macros
KDPEDMB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R530 PSY UI36951
UP16/04/14 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 February 2017