IBM Support

PI57332: WHEN RESUMING MOBILEFIRST APPLICATION FROM BACKGROUND, A NEW WEBVIEW INSTANCE IS CREATED AND PREVIOUS INSTANCE IS NOT CLEARED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The Cordova Webview does not get destroyed when the MobileFirst
    Platform Foundation application goes to the background. When the
    application resumes, a new WebView instance is created and the
    old WebView is still not cleared. These uncleared WebViews will
    take up memory and should be properly destroyed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users that use the Cordova WebView for Android.          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The Cordova WebView does not get destroyed when the          *
    * application goes into the background. It remains in a        *
    * detached state, and will get cleared only when the Android   *
    * OS kills it to free up memory. Resuming the application will *
    * create a new Cordova WebView instance. When the Cordova      *
    * WebView handles being destroyed, it never calls the Android  *
    * WebView's destroy() method, thus it lingers around in a      *
    * detached state. Calling that method, the Cordova WebView     *
    * will have the expected behavior.                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • After installing the iFix, rebuild the application.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI57332

  • Reported component name

    MFPF/WORKLIGHT

  • Reported component ID

    5725I4301

  • Reported release

    630

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-02-16

  • Closed date

    2016-02-25

  • Last modified date

    2016-02-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MFPF/WORKLIGHT

  • Fixed component ID

    5725I4301

Applicable component levels

  • R630 PSY

       UP

  • R700 PSY

       UP

  • R710 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: