A fix is available
APAR status
Closed as program error.
Error description
Client using A0000 for an absolute Midnight Time specification see current timestamp instead of midnight.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM HourGlass users using * * HourGlass A0000 "Absolute Midnight" * * (local) time adjustments. * **************************************************************** * PROBLEM DESCRIPTION: A0000 or TIME=A0000 or //HGA0000 etc. * * HourGlass time adjustments were * * intended to mean "Absolute Midnight", * * for the local time. * * * * To be clear, these time adjustments * * are intended to be at the start of the * * day on chosen adjusted date, and not * * the end of that adjusted date. * * * * Also, to be clear, unlike other * * HourGlass time adjustments with zero * * hours and zero minutes, was NOT * * intended to mean "Current Time". * * Unfortunately, some of the HourGlass * * code has accidentally yielded this * * undesired result. * **************************************************************** * RECOMMENDATION: Apply the PTF. * ****************************************************************
Problem conclusion
*************************************************************** * FIX DESCRIPTION: * * AGGCC and AGGPLT have been modified to * * stop "ignoring A0000" HourGlass time * * adjustments during the CICS HourGlass * * enablement function they implement, * * and thus yielding "Current Real Local * * Time" instead, except for ASKTIME * * ABSTIME which already correctly * * yielded "Absolute Midnight". * * * * AGGCUST has been modified to accept * * "hard coded" time adjustments with * * zero hours and zero minutes, including * * A0000, without yeilding an error * * message instead. However, other than * * message instead. However, other than * * A0000, these adjustments have no * * different effect than the default, * * which is "Current Time". And, of * * course, just like other hard coded * * time adjustments, any other time * * adjustments from Control Elements or * * from JCL via Programmer Name field or * * HourGlass recognized DD Names, will * * override these values. * * * * AGGELIG has been modified to accept * * "hard coded" "Absolute Midnight" A0000 * * HourGlass time adjustments. It has * * also been modified to make sure it * * ignores invalid programmer name field * * HourGlass DD names. * * * * AGGLSPC has been modified to stop * * ignoring A0000 HourGlass time * * adjustments for PC Time Services and * * integration patch requests. * * * *************************************************************** * PRODUCT ELEMENTS AFFECTED BY THIS FIX: * *************************************************************** * NEW ELEMENTS ADDED: * * None. * * * *************************************************************** * EXISTING ELEMENTS MODIFIED: * * For HourGlass V610 (5697-P29-00): * * SAGGLOAD(AGGCC ).#000029 2016/03/02.13:17:23.PI56127 * * SAGGLOAD(AGGFRONT).#000029 2016/02/13.12:40:58.PI56127 * * (AGGELIG ).#000067 2016/02/26.19:37:03.PI56127 * * SAGGLOAD(AGGLSPC ).#000091 2016/03/01.13:21:26.PI56127 * * SAGGLOAD(AGGPLT ).#000009 2016/02/13.21:11:57.PI56127 * * SAGGLOAD(AGGUC ).#000014 2016/02/15.14:30:43.PI56127 * * * *************************************************************** * EXISTING ELEMENTS DELETED: * * None. * * * *************************************************************** * IMPLEMENTATION: * * After applying this PTF, all users * * need to stop and restart the CICS * * regions where HourGlass is running. * * * * After installing the PTF it will be * * necessary to reexecute the HourGlass * * customization job and stop/restart the * * HourGlass product via, an AGGOFF/AGGON * * command sequence * * * ***************************************************************
Temporary fix
Comments
APAR Information
APAR number
PI56127
Reported component name
IBM HOURGLASS
Reported component ID
5655U4200
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-01-28
Closed date
2016-03-14
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI36181
Modules/Macros
AGGCC AGGFRONT AGGLSPC AGGPLT AGGUC
Fix information
Fixed component name
IBM HOURGLASS
Fixed component ID
5655U4200
Applicable component levels
R610 PSY UI36181
UP16/03/16 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
30 April 2020