A fix is available
APAR status
Closed as program error.
Error description
1. A PING request shows incorrect information in event x'3E', the origin DS name of PING_IMS is incorrectly propagated to the target DS name field. 2. If sending of a SendOnly transaction to OTMA is delayed for any reason, it can result in the trigger event for a SendOnly transaction being issued while the next SendOnly transaction on the same ICON session is being processed by the message exit. This can cause the CEX SVT control block to be cleared for the first transaction after the SVT has been updated with the results of message exit processing for the second SendOnly transaction. This corruption of the CEX SVT can result in several errors but is most noticable when it results in routing errors and/or the HWSS0742W message. Summary of changes: 1. Add exception code to handle the PING case. 2. A change in SVT maintenance for SendOnly transaction is made to delay cleanup of the CEX SVT so that it is not impacted by a delayed trigger event.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Connect Extensions V2.4 * **************************************************************** * PROBLEM DESCRIPTION: Multiple issues. * **************************************************************** * RECOMMENDATION: * **************************************************************** 1. A PING request shows incorrect information in event x'3E', the origin DS name of PING_IMS is incorrectly propagated to the target DS name field. 2. If sending of a SendOnly transaction to OTMA is delayed for any reason, it an result in the trigger event for a SendOnly transaction being issued while the next SendOnly transaction on the same ICON session is being processed by the message exit. This can cause the CEX SVT control block to be cleared for the first transaction after the SVT has been updated with the results of message exit processing for the second SendOnly transaction. This corruption of the CEX SVT can result in several errors but is most noticable when it results in routing errors and/or the HWSS0742W message.
Problem conclusion
1. Add exception code to handle the PING case. 2. A change in SVT maintenance for SendOnly transaction is made to delay cleanup of the CEX SVT so that it is not impacted by a delayed trigger event.
Temporary fix
Comments
APAR Information
APAR number
PI55657
Reported component name
IMS CONNECT EXT
Reported component ID
5655K4800
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-01-19
Closed date
2016-02-26
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI35720
Modules/Macros
CEXEXRTR CEXTECL1
Fix information
Fixed component name
IMS CONNECT EXT
Fixed component ID
5655K4800
Applicable component levels
R240 PSY UI35720
UP16/03/02 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.