IBM Support

PI55413: CICS BBO (WebSphere) link server abends with WRITEQ TSQ BBO* error eibresp: 16 eibresp2: 0

Fixes are available

8.5.5.10: WebSphere Application Server V8.5.5 Fix Pack 10
8.5.5.11: WebSphere Application Server V8.5.5 Fix Pack 11
16.0.0.2: WebSphere Application Server Liberty 16.0.0.2
16.0.0.3: WebSphere Application Server Liberty 16.0.0.3
16.0.0.4: WebSphere Application Server Liberty 16.0.0.4
8.0.0.13: WebSphere Application Server V8.0 Fix Pack 13
8.5.5.12: WebSphere Application Server V8.5.5 Fix Pack 12
8.0.0.14: WebSphere Application Server V8.0 Fix Pack 14
8.5.5.13: WebSphere Application Server V8.5.5 Fix Pack 13
17.0.0.1: WebSphere Application Server Liberty 17.0.0.1
8.0.0.15: WebSphere Application Server V8.0 Fix Pack 15
17.0.0.2: WebSphere Application Server Liberty 17.0.0.2
17.0.0.3: WebSphere Application Server Liberty 17.0.0.3
17.0.0.4: WebSphere Application Server Liberty 17.0.0.4
18.0.0.1: WebSphere Application Server Liberty 18.0.0.1
18.0.0.2: WebSphere Application Server Liberty 18.0.0.2
8.5.5.14: WebSphere Application Server V8.5.5 Fix Pack 14
18.0.0.3: WebSphere Application Server Liberty 18.0.0.3
18.0.0.4: WebSphere Application Server Liberty 18.0.0.4
19.0.0.1: WebSphere Application Server Liberty 19.0.0.1
8.5.5.15: WebSphere Application Server V8.5.5 Fix Pack 15
19.0.0.2: WebSphere Application Server Liberty 19.0.0.2
19.0.0.3: WebSphere Application Server Liberty 19.0.0.3
19.0.0.4: WebSphere Application Server Liberty 19.0.0.4
19.0.0.5: WebSphere Application Server Liberty 19.0.0.5
19.0.0.6: WebSphere Application Server Liberty 19.0.0.6
19.0.0.7: WebSphere Application Server Liberty 19.0.0.7
19.0.0.8: WebSphere Application Server Liberty 19.0.0.8
19.0.0.9: WebSphere Application Server Liberty 19.0.0.9
19.0.0.10: WebSphere Application Server Liberty 19.0.0.10
19.0.0.11: WebSphere Application Server Liberty 19.0.0.11
19.0.0.12: WebSphere Application Server Liberty 19.0.0.12
20.0.0.1: WebSphere Application Server Liberty 20.0.0.1
20.0.0.2: WebSphere Application Server Liberty 20.0.0.2
8.5.5.17: WebSphere Application Server V8.5.5 Fix Pack 17
20.0.0.3: WebSphere Application Server Liberty 20.0.0.3
20.0.0.4: WebSphere Application Server Liberty 20.0.0.4
20.0.0.5: WebSphere Application Server Liberty 20.0.0.5
20.0.0.6: WebSphere Application Server Liberty 20.0.0.6
20.0.0.7: WebSphere Application Server Liberty 20.0.0.7
20.0.0.8: WebSphere Application Server Liberty 20.0.0.8
20.0.0.9: WebSphere Application Server Liberty 20.0.0.9
20.0.0.10: WebSphere Application Server Liberty 20.0.0.10
20.0.0.11: WebSphere Application Server Liberty 20.0.0.11
20.0.0.12: WebSphere Application Server Liberty 20.0.0.12
8.5.5.20: WebSphere Application Server V8.5.5.20
8.5.5.18: WebSphere Application Server V8.5.5 Fix Pack 18
8.5.5.19: WebSphere Application Server V8.5.5 Fix Pack 19
8.5.5.16: WebSphere Application Server V8.5.5 Fix Pack 16
8.5.5.21: WebSphere Application Server V8.5.5.21

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running WOLA in CICS and the CICS BBO link server abends,
    the following message is seen in the CICS output:
        BBOA8799E A WRITEQ TSQ BBOnnnnn error occurred with
    eibresp: 16 eibresp2: 0.
        .
    This error should create an SVCDUMP of the CICS address space.
    When reviewing the CICS dump, one will find that the same queue
    name (which looks like BBOxxxx) was used for both commands:
    EXEC CICS START
    EXEC CICS WRITEQ TS QUEUE
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All WebSphere Application Server V8.0 and   *
    *                  V8.5 users of WebSphere Optimized local     *
    *                  Adapters (WOLA) connecting to CICS using    *
    *                  the WOLA CICS link server.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: The CICS Link server abends             *
    *                      attempting to write to a CICS TS Queue  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Customers using WebSphere Optimized
    Local Adapters CICS Link Server
    experience a link server abend with the following message:
    BBOA8799E A WRITEQ TSQ BBOnnnnn error
    occurred with eibresp: 16 eibresp2: 0.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI55413

  • Reported component name

    WEBSPHERE FOR Z

  • Reported component ID

    5655I3500

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-01-14

  • Closed date

    2016-03-28

  • Last modified date

    2016-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE FOR Z

  • Fixed component ID

    5655I3500

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS7K4U","label":"WebSphere Application Server for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: