A fix is available
APAR status
Closed as program error.
Error description
When using NOLOGRO YES, a CHKP call will return an NL status code. There is logic in IRTIVPG1 that causes the program to reset to the last-returned root segment when a non-blank status code is returned from the CHKP call. This causes the loop.
Local fix
Use NOLOGRO NO when running the IRTIVPG1 IVP program.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Program Restart Facility V2R2. * **************************************************************** * PROBLEM DESCRIPTION: IVP program IRTIVPG1 loops when using * * NOLOGRO YES * **************************************************************** * RECOMMENDATION: * **************************************************************** When using NOLOGRO YES, a CHKP call will return an NL status code. There is logic in IRTIVPG1 that causes the program to reset to the last-returned root segment when a non-blank status code is returned from the CHKP call. This causes the loop.
Problem conclusion
IRTIVPG1 has been modified to correct this problem.
Temporary fix
Comments
APAR Information
APAR number
PI53569
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-12-04
Closed date
2015-12-24
Last modified date
2016-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI34097
Modules/Macros
IRTIVPG1
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI34097
UP16/01/05 P F601
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]