Fixes are available
8.5.5.9: WebSphere Application Server V8.5.5 Fix Pack 9
8.5.5.10: WebSphere Application Server V8.5.5 Fix Pack 10
8.5.5.11: WebSphere Application Server V8.5.5 Fix Pack 11
8.0.0.13: WebSphere Application Server V8.0 Fix Pack 13
8.5.5.12: WebSphere Application Server V8.5.5 Fix Pack 12
8.0.0.14: WebSphere Application Server V8.0 Fix Pack 14
8.5.5.13: WebSphere Application Server V8.5.5 Fix Pack 13
8.0.0.15: WebSphere Application Server V8.0 Fix Pack 15
8.5.5.14: WebSphere Application Server V8.5.5 Fix Pack 14
8.5.5.15: WebSphere Application Server V8.5.5 Fix Pack 15
8.5.5.17: WebSphere Application Server V8.5.5 Fix Pack 17
8.5.5.20: WebSphere Application Server V8.5.5.20
8.5.5.18: WebSphere Application Server V8.5.5 Fix Pack 18
8.5.5.19: WebSphere Application Server V8.5.5 Fix Pack 19
8.5.5.16: WebSphere Application Server V8.5.5 Fix Pack 16
8.5.5.21: WebSphere Application Server V8.5.5.21
APAR status
Closed as program error.
Error description
During normal STOP of a WebSphere server, the following SVCDUMP message was emitted: IEA794I SVC DUMP HAS CAPTURED: DUMPID=031 REQUESTED BY JOB (BBONAGNT) DUMP TITLE=COMPON=WEBSPHERE Z/OS, COMPID=5655I3500, ISSUER=BBORADMP, ABEND IN PC ROUTINE BBOCLSPC Note that the server being stopped is called BBOS0001, and BBONAGNT is the nodeagent for this server. The server does complete its normal shutdown, and the nodeagent does not terminate.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server V8.0 and V8.5. * **************************************************************** * PROBLEM DESCRIPTION: WebSphere Application server for z/OS * * receives an ABEND0C4 during shutdown. * **************************************************************** * RECOMMENDATION: * **************************************************************** A controller was stopping and had proceeded far enough to have freed some control structures. At this time a Local Communication (LCOM) request for a new connection was made. This invoked the PC routine, bboclspc. Under the PC routine an ABENDS0C4 occurred referencing the BOAX structure. The BOAX was freed as part of the server shutting down.
Problem conclusion
Code was modified in the LCOM PC routine, bboclspc, to skip the reference to the BOAX if it detects that the server is shutting down. APAR PI53425 is currently targeted for inclusion in Fix Packs 8.0.0.13 and 8.5.5.9 of WebShere Application Server. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980 In addition, please refer to URL: http://www.ibm.com/support/docview.wss?rs=404&uid=swg27006970 for Fix Pack PTF information.
Temporary fix
Comments
APAR Information
APAR number
PI53425
Reported component name
WEBSPHERE FOR Z
Reported component ID
5655I3500
Reported release
800
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-12-02
Closed date
2015-12-03
Last modified date
2015-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBSPHERE FOR Z
Fixed component ID
5655I3500
Applicable component levels
R800 PSY
UP
Document Information
Modified date:
28 April 2022