IBM Support

PI53361: EXCESSIVE VALUE FOR CPU TIME IN EXCEPTION

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FPEV0100I xxxx FIELD FOUND IN EXCEPTION ADRECETT,ELAPSED TIME IN
    APPLICATION (CLASS 1) PLAN,xxxxxxx ,DISTSERV,SERVER
    ,xxxx,2015-10-19-11.41.51.097407P,3654261711.1,>,7000
    ,GA8882B9-C265    -CFB881131C09,
    145524
    
    
    the value is always 3,654,###,###.#
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the PE Server subtask monitors a   *
    *                      DB2 subsystem and Autoexception is      *
    *                      activated and a threshold value for     *
    *                      field ADRECETT (elapsed time in         *
    *                      application class 1) or ADCPUTP (CPU    *
    *                      time class 7) is specified in the       *
    *                      used threshold data set, a threshold    *
    *                      exception is reported although the      *
    *                      threshold value is not exceeded.        *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    The performance data, retrieved from DB2 to calculate fields
    ADRECETT and ADCPUTP, may be set or not depending on the thread
    activity at the time of data retrieval. The data retrieved are
    not validated before being used for calculations.
    
    PROBLEM CONCLUSION:
    The code has been corrected accordingly to validate the
    data retrieved.
    
    KEYWORDS:
    AUTOEXCEPTION PERIODIC EXCEPTION FPEV0100I ADCPUTP
    ADRECETT
    

Problem conclusion

  • The code has been corrected accordingly to validate the
    data retrieved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI53361

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-12-01

  • Closed date

    2016-02-17

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI35419 UI35420

Modules/Macros

  • DGOFECAL DGOFECA2 DGOFEDPM DGOMFTAG DGOVMSTR DGOVSADJ DGOVSADK
    DGOVSAGG DGOVSCTH DGOVSDTT DGOVSTAG
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R520 PSY UI35419

       UP16/02/19 P F602

  • R530 PSY UI35420

       UP16/02/19 P F602

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 February 2017