PI52695: ALLOW CONTROL OVER WHETHER IDAA DATA GETS RELOADED AS A RESULT OF A CHANGE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Allow control over whether IDAA data gets reloaded as a result
    of a change.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the DB2 Administration Tool         *
    *                 for z/OS who make changes to the             *
    *                 table definitions that are accelerated.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: This new function will allow the user   *
    *                      to have control over whether IBM        *
    *                      DB2  Analytics Accelerator for IBM      *
    *                      z/OS  (IDAA) data gets reloaded as      *
    *                      a result of a change.                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Prior to this APAR, when the definition of a DB2 table is
    changed that involved dropping and recreating the table, the
    table on the accelerator is removed, added back and the data
    is reloaded.
    
    The option used on panel ADB2PCO 'Options for Change
    Functions ' to accomplish this was:
    
    Reload accelerated tables .. YES (Yes/No. Default is Yes.)
    
    With this APAR, there is more granularity added for taking care
    of the tables on the accelerator side.
    
    Here are the new options and explanation of what each can do:
    
    1 - The following option can determine whether to recreate the
    accelerated tables:
    
    Recreate accelerated tables  . . . YES (Yes/No. Default is Yes)
    
    2- The following option will allow control over whether IDAA
    data gets reloaded when a table is dropped and recreated:
    
    Reload accelerated tables  . . . . YES (Yes/No. Default is Yes)
    
    3- The following option helps in removing the table from the
    accelerator when a table is dropped from DB2 side:
    
    Remove deleted accelerated tables. YES (Yes/No. Default is Yes)
    

Problem conclusion

Temporary fix

Comments

  • Enhancement delivered.
    

APAR Information

  • APAR number

    PI52695

  • Reported component name

    DB2 ADMIN TOOL

  • Reported component ID

    568851500

  • Reported release

    B20

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-11-18

  • Closed date

    2015-12-18

  • Last modified date

    2016-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    ADBASW   ADBCCM   ADBCCMM  ADBCDTS  ADBCEST
    ADBCMPDB ADBCNBVF ADBCRCR  ADBCSPG  ADBDAT   ADBDK    ADBEALT
    ADBHPCO  ADBLI    ADBNSPB  ADBPA    ADBPA1   ADBSALT  ADBSPCO
    ADBTEPI  ADBTEPR  ADBTEPU  ADBTEP2  ADBV99   ADB2CID  ADB2CME
    ADB2CMF  ADB2CMO  ADB2CMP  ADB2CMR  ADB2CMS  ADB2CMT  ADB2CMU
    ADB2CM1  ADB2CM2  ADB2CM3  ADB2C11A ADB2FMT  ADB2MSK  ADB2MSQ
    ADB2PA   ADB2PA3  ADB2PA4  ADB2PA5  ADB2PA6  ADB2PA7  ADB2PCO
    ADB2REG  ADB2REH  ADB2WCL  ADB2WVL  ADB27AC  ADB28MC  ADB5000
    ADB7000
    

Fix information

  • Fixed component name

    DB2 ADMIN TOOL

  • Fixed component ID

    568851500

Applicable component levels

  • RB20 PSY UI33960

       UP15/12/23 P F512

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSCVQTD","label":"IBM Db2 Administration Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"11.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
04 January 2016