A fix is available
APAR status
Closed as program error.
Error description
The default value of HPIO control statement for Load API when using PGM=HPSRRC00 and all libraries in the STEPLIB DD are APF-authorized has been changed from YES to NO by applying APAR PK88818.
Local fix
Specify HPIO=YES in control statements.
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM IMS High Performance Load * * for z/OS Version 2 Release 1 (FMID=H1IM210). * **************************************************************** * PROBLEM DESCRIPTION: The default value of HPIO statement for * * Load API has been changed to NO. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The default value of HPIO statement for Load API has been changed to NO.
Problem conclusion
This APAR fixes the following problem: The default value of HPIO control statement for Load API when using PGM=HPSRRC00 and all libraries in the STEPLIB DD are APF-authorized has been changed from YES to NO by applying APAR PK88818.
Temporary fix
Comments
APAR Information
APAR number
PI52163
Reported component name
IMS HIGH PERF L
Reported component ID
5655E0700
Reported release
210
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-11-09
Closed date
2015-12-14
Last modified date
2016-01-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI33767
Modules/Macros
HPSRRRI0 HPSRRRI9
Fix information
Fixed component name
IMS HIGH PERF L
Fixed component ID
5655E0700
Applicable component levels
R210 PSY UI33767
UP15/12/16 P F512
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89F","label":"IMS HP Load"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]