IBM Support

PI51331: IMS V14 ABENDU1002-030 AFTER PUTTING ON FIX FOR PI46998 15/11/06 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABENDU1002-030 in DFS3DU10.
    .
    It appears that the last qualifier in the directory dataset
    name(s) are set incorrectly (DI0100).  They should be DI010001
    and DI010002.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IMS V14 users of the IMS Catalog with IMS-managed ACBs       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * With the fix for APAR PI46998 installed an abendU1002 RC30   *
    * occurs in the IMS Catalog Populate utility when specifying   *
    * MANAGEDACBS=UPDATE or MANAGEDACBS=STAGE. MSGIKJ56228I and    *
    * MSGIKJ56868I indicate that a data set could not be found.    *
    * The data set name in the message refers to one of the        *
    * existing directory data sets, but the last two characters of *
    * the data set name are missing.                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Install corrective service for APAR/PTF.                     *
    ****************************************************************
    The fix for APAR PI46998 changed the format of the last
    qualifier of the catalog directory data set names from DIrrnnnn
    to DIvnnn. (rr or r is a code for the IMS release number and
    nnnn or nnn is the sequence number of a specific catalog
    directory data set.) This last qualifier was shortened from
    eight to six characters to allow the longest possible high-level
    qualifiers to produce data set names that fit within the
    44-character maximum data set name length.
    
    In the failing scenario an existing catalog directory was used
    because MANAGEDACBS=UPDATE or MANAGEDACBS=STAGE was used, and
    the existing directory data set names had the original longer
    (eight-character) suffix. (In this particular case the
    high-level qualifiers of the name were short enough that the
    44-character limit wouldn't have been exceeded.) The code that
    was trying to allocate these data sets incorrectly interpreted
    only the first six characters of the last qualifier of the data
    set name, thus causing the allocation failure.
    

Problem conclusion

  • The code in module DFS3DU10 to allocate existing catalog
    directory data sets was corrected to use the entire data set
    name previously recorded in the bootstrap data set (last
    qualifier of BSDS).
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI51331

  • Reported component name

    IMS V14

  • Reported component ID

    5635A0500

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-27

  • Closed date

    2015-11-03

  • Last modified date

    2015-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI32635

Modules/Macros

  • DFS3DU10
    

Fix information

  • Fixed component name

    IMS V14

  • Fixed component ID

    5635A0500

Applicable component levels

  • R400 PSY UI32635

       UP15/11/05 P F511 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEPH2","label":"IMS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"14.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 December 2023