IBM Support

PI51298: CT/ENGINE ABEND S000 U2008 AT AF99782E (KDPAUTOD.KDPASSCT+416)

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • We have two LPARs in our SYSPLEX: HERA and ZEUS. HERA was
    upgraded and
    ZEUS is still at OMEGAMON for DB2 V5.2.  OMEGAMON for z/OS and
    OMEGAMON
    for CICS are both at V5R3; OMEGAMON for IMS is still at V5R1.
    On the TOM on ZEUS I see all of the DB2 subsystems along with
    data from
    the other monitors. On the TOM on HERA I see no DB2 subsystems
    but I do
    see data from the other monitors..
    

Local fix

  • shut down the agents, the TEMS and the OMPE collector.
    Then restart them in this order
    1. the OMPE collector. Make sure the collector is up and running
       before moving to the next item
    2. the TEMS
    3. finally, start the agents
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - TEMA / TEMS                                *
    ****************************************************************
    * PROBLEM DESCRIPTION: CT/ENGINE ABEND S000 U2008 AT AF99782E  *
    *                      (KDPAUTOD.KDPASSCT+416)                 *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    After an IPL, if the agent address looks for a control block
    that the collector address space hasn't had a chance to build
    yet, the agent will abend.
    
    PROBLEM CONCLUSION:
    Add code to allow the agent to wait for the collector to
    build its registration table.
    
    KEYWORDS:
    U2008 KDPAUTOD KDPASSCT CT/ENGINE AGENT
    

Problem conclusion

  • Add code to allow the agent to wait for the collector to
    build its registration table.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI51298

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-27

  • Closed date

    2016-01-29

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI34853

Modules/Macros

  • KD5AGENT KD5AUTO1
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R530 PSY UI34853

       UP16/01/30 P F601

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: