IBM Support

PI50674: IMS IS SHUTDOWN DURING RECOVERDM RUN AND THE JOB OUTPUT STATES THAT MESSAGES HAVE BEEN RELOADED WHEN THEY HAVEN'T BEEN

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During a RECOVERDM job run the following messages are received
    in the RECOVERDM job output when IMS is shutdown:
     IQC7003E - RC=0010  QCF CRITICAL ERROR IN MODULE  IQCBTQCF IMS
     RC=00000010,RSN=ERROR
     IQC7017E PROCESSING HAS STOPPED DUE TO SYNCPOINT ERROR
     IQC4998I PIMS41CR RC=0000 AIBRC=0000 AIBRS=0000
    These messages are expected in such case, when IMS is shutdown,
    but can differ depending on where IMS and the job completes.
    
    In this case the job output ends with RC=00 and states that
    messages have been reloaded when in fact they have not been
    reloaded.  Adjustments will be made to have the job end with
    RC=08 in such case to notify the user the messages passed to
    IMS have not been committed.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of QCF V3.1                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS is shutdown during RECOVERDM run    *
    *                      and the job output states that messages *
    *                      have been reloaded when, in fact, they  *
    *                      have not.                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    During a RECOVERDM job run the following messages are received
    in the RECOVERDM job output when IMS is shutdown:
     IQC7003E - RC=0010  QCF CRITICAL ERROR IN MODULE  IQCBTQCF IMS
     RC=00000010,RSN=ERROR
     IQC7017E PROCESSING HAS STOPPED DUE TO SYNCPOINT ERROR
     IQC4998I PIMS41CR RC=0000 AIBRC=0000 AIBRS=0000
    These messages are expected in such case, when IMS is shutdown,
    but can differ depending on where IMS and the job completes.
    In this case the job output ends with RC=00 and states that
    messages have been reloaded when in fact they have not been
    reloaded.  Adjustments will be made to have the job end with
    RC=08 in such case to notify the user the messages passed to
    IMS have not been committed.
    

Problem conclusion

  • When a Syncpoint Error occurs during the LOAD step of a
    RECOVERDM job or during a LOAD job, the user will be notified
    with 2 new messages.
    1. IQC7020E No messages passed to IMS have been committed
    2. IQC5516I No messages passed to IMS have been committed
    Also, if a Syncpoint Error does occur, the LOAD step will
    end with RC=08 instaed of RC=00 as it did before.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI50674

  • Reported component name

    IMS QUEUE CNTL

  • Reported component ID

    5697E9900

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-15

  • Closed date

    2016-05-24

  • Last modified date

    2016-07-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI38118

Modules/Macros

  • IQCBTQCF IQCM1ENU IQCM2ENU IQCXCTRL
    

Fix information

  • Fixed component name

    IMS QUEUE CNTL

  • Fixed component ID

    5697E9900

Applicable component levels

  • R310 PSY UI38118

       UP16/06/02 P F606

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: