IBM Support

PI50646: IC OF DB NOT AUTHORIZED VIA DBDSGORUP

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IC of DB not authorized via DBDSGORUP
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR fixes following two problems: *
    *                      - IMS HP Image Copy does not issue      *
    *                        necessary IMS Command through the IMS *
    *                        Tools Online System Interface(TOSI),  *
    *                        even if the target database is        *
    *                        accessed by other applications with   *
    *                        the update mode.  As a result, IMS HP *
    *                        Image Copy can not obtain database    *
    *                        access authorization for Batch Image  *
    *                        Copy process with DFS047A message     *
    *                        ( MSGDFS047A ) for DL/I database      *
    *                        (DL/I DB) and High Availability Large *
    *                        Databases (HALDB), or with DFS3710A   *
    *                        message ( MSGDFS3710A ) for Data      *
    *                        Entry Database(DEDB).                 *
    *                                                              *
    *                      - The Data Set Statistics report shows  *
    *                        incorrect value for DATA SET GROUP    *
    *                        NUMBER and AREA NUMBER.               *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes following two problems:
    - IMS HP Image Copy does not issue necessary IMS Command
      through the IMS Tools Online System Interface(TOSI), even if
      the target database is accessed by other applications with
      the update mode.  As a result, IMS HP Image Copy can not
      obtain database access authorization for Batch Image Copy
      process with DFS047A message ( MSGDFS047A ) for DL/I database
      (DL/I DB) and High Availability Large Databases (HALDB),
      or with DFS3710A message ( MSGDFS3710A ) for Data Entry
      Database(DEDB).
      This problem occurs under the following conditions:
      - The target database is accessed by other applications with
        the update mode.
      - More than one DL/I database, HALDB partition, DEDB area
        name start with same character strings and one of their
        name is comprised in others in ICEIN DD statement.
        And longer target database name appears earlier.
      - TOIAUTO=Y|O or TOIAUTO_Q=Y are specified in ICEIN DD
        statement.
    d
    - The Data Set Statistics report shows incorrect value for DATA
      SET GROUP NUMBER and AREA NUMBER when the following condition
      are satisfied.
      - FABJSTAT DD is specified.
      - At DL/I database:
        - The target database is a data set group(DSG).
        - More than one of data sets in the DSG are expected to be
          processed, and these DD name start with same character
          strings.
        - The one of their DD name is comprised in others.
        - The longer DD name appears earlier.
      - At DEDB:
        - More than one of area in DEDB are expected to be
          processed, and these area name start with same character
          strings.
        - The one of their area name is comprised in others.
        - The longer area name appears earlier.
    
    The cause of the problem is that IMS HP Image Copy does not
    creating process, IMS HP Image Copy compares the data field
    value to the data in the control block that has been created.
    However it compares them without consideration for the length
    of data name.  As a result, IMS HP Image Copy determines that
    same data has been already existed in the control block.
    Then, the necessary IMS command process is not done or
    incorrect value is reported.
    

Problem conclusion

  • By this APAR, IMS Image Copy compares the data field value to
    the data in the control block with consideration for the length
    of data name. And, IMS HP Image Copy determines the correct
    data in the control block.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI50646

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-10-15

  • Closed date

    2015-11-12

  • Last modified date

    2015-12-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI32910

Modules/Macros

  • FABJDBDA FABJDBDB FABJDBD2 FABJDBD3 FABJDBD4
    FABJDBD9 FABJTOI
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI32910

       UP15/11/14 P F511

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 December 2020