A fix is available
APAR status
Closed as program error.
Error description
After IMS V12 APAR PI20107(PTF UI30464) is applied, Advanced ACBGEN ends with ABENDU1015. The cause of the problem is, Advanced ACBGEN cannot hook into module DFSDLB00 with APAR/PTF PI20107/UI30464 applied.
Local fix
Keywords: IMSV12COEX/K IMSV13COEX/K
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use the Advanced ACBGEN utility. * **************************************************************** * PROBLEM DESCRIPTION: After IMS V12 APAR PI20107 or IMS V13 * * APAR PI46619 is applied, Advanced * * ACBGEN ends with ABENDU1015. * * When running Advanced ACBGEN under * * DFS3UACB (ACB Generation and Catalog * * Populate utility) to generate ACB * * members also ends with ABENDU1015. In * * each case, Advanced ACBGEN does not * * generate ACBLIB members and ends with * * MSGFABQ9912E UNABLE TO HOOK DFSDLBL0. * **************************************************************** * RECOMMENDATION: * **************************************************************** This APAR fixes Advanced ACBGEN not to end with ABENDU1015 and generates ACBLIB members with IMS V12 after APAR PI20107 is applied. This APAR also fixes Advanced ACBGEN under DFS3UACB (ACB Generation and Catalog Populate utility). IMS V12 APAR PI20107 changes IMS V12 module DFSDLB00 that Advanced ACBGEN depends its structure to hook into and work with, therefore Advanced ACBGEN becomes unable to hook into appropriate processes in the changed module. The Advanced ACBGEN module FABQHUK2 which hooks IMS modules is fixed to hook correctly with IMS V12 after APAR PI20107 is applied. ABENDU1015 problem is fixed with this APAR, but the behavior of IMS V12 Advanced ACBGEN utility with BLDPSB=NO which works same as IMS ACBGEN with PI20107 will be provided by another new APAR. The same problem is occurred when Advanced ACBGEN runs with IMS V13 after APAR PI46619 is applied. This APAR also fixes the problem.
Problem conclusion
The following module has been changed to fix the above problem: - FABQHUK2 KEYWORDS: IMSV12TGT/K,IMSV13TGT/K
Temporary fix
Comments
APAR Information
APAR number
PI48514
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-10
Closed date
2015-10-15
Last modified date
2016-03-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI32069
Modules/Macros
FABQHUK2
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI32069
UP15/10/17 P F510
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
22 March 2016