Error description

  • Online cloning generates an extra step after the IMSUPDATE
    procedure. This step is designed so as the target subsystem will
    not have issues due to open logs that were cloned. This is
    achieved by running DBRC, after the IMSUPDATE step, with:
    CHANGE.SUBSYS SSID(ssid) ABNORMAL
    GENJCL.CLOSE SSID(ssid)
    This step is not generated for ISPF if online cloning is not
    chosen. However if the source system was not actually running at
    the time then the above step will end with RC=12.
    The flower box description for this step is confusing for the
    customer.
    //**************************************************************
    //* CLOSE ONLINE LOG FOR TARGET IMS
    //* THIS STEP IS NOT NEEDED IF IMS WAS NORMALLY SHUTDOWN PRIOR
    TO
    //* THE COPY STEP. IF THE ONLINE LOG WAS ALREADY CLOSED THEN
    DBRC
    //* WILL END WITH RC=12.
    //**************************************************************
    This also ends the job with RC=12 which can impact dependent job
    processing.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of online system cloning.          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Improvements for the LOG CLOSE          *
    *                      functionality                           *
    ****************************************************************
    * RECOMMENDATION: Install maintenance for this APAR/PTF.       *
    ****************************************************************
    Online cloning generates an extra step after the IMSUPDATE
    procedure. This step is designed so as the target subsystem will
    not have issues due to open logs that were cloned. This is
    achieved by running DBRC, after the IMSUPDATE step, with:
    
    CHANGE.SUBSYS SSID(ssid) ABNORMAL
    GENJCL.CLOSE SSID(ssid)
    
    This step is not generated for ISPF if online cloning is not
    chosen. However if the source system was not actually running
    at the time then the above step will end with RC=12. The flower
    box description for this step is confusing for the users.
    
    //* CLOSE ONLINE LOG FOR TARGET IMS
    //* THIS STEP IS NOT NEEDED IF IMS WAS NORMALLY SHUTDOWN PRIOR
    //* THE COPY STEP. IF THE ONLINE LOG WAS ALREADY CLOSED THEN
    //* WILL END WITH RC=12.
    
    This also ends the job with RC=12 which can impact dependent job
    processing.
    

Problem conclusion

  • Extra step after IMSUPDATE is removed, LOG CLOSE processing is
    Initiated automatically by the IMSUPDATE step if necessary.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI48109

  • Reported component name

    IMS CLONING TOO

  • Reported component ID

    5655U9100

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2015-09-02

  • Closed date

    2017-10-25

  • Last modified date

    2018-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI51409

Modules/Macros

  •    GCLDYNAL GCLIUPDT GCLIUPD2 GCLLITS  GCLONEJB
    GCL00320 GCL00329 GCL2DOUT GCL2GNJC GCL2MAIN HAEQ120J
    

Fix information

  • Fixed component name

    IMS CLONING TOO

  • Fixed component ID

    5655U9100

Applicable component levels

  • R120 PSY UI51409

       UP17/10/31 P F710

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY5","label":"IMS Cloning Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date:
21 October 2020