IBM Support

PI47900: PANEL CKZ1GFSJ DISPLAYS AN ERRONEOUS MESSAGE WHEN REBUILD-INDEX-EXECUTE "YES" IS SPECIFIED.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Erroneous message and stop processing on panel CKZ1GFSJ when
    REBUILD-INDEX-EXECUTE   "YES"  is specified.
    .
    When PF3 is entered on panel CKZ1GFSJ to create the source and
    target jobs, the following message is displayed and one is
    returned to panel CKZ1BDCJ.
    .
    "CKZ414E - The TARGET-JOB-INDEX-REBUILD-DDN value must be
    provided in the COPY command when REBUILD-INDEXES-EXECUTE is set
    to "YES" in the SET command".
    .
    TARGET-JOB-INDEX-REBUILD-DDN  is NOT required for
    REBUILD-INDEX-EXECUTE YES. No job template is used by this
    process therefore no DDName is required.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Cloning Tool.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Erroneous message and stop processing   *
    *                      on panel CKZ1GFSJ when                  *
    *                      REBUILD-INDEX-EXECUTE   "YES"  is       *
    *                      specified.                              *
    *                      When PF3 is entered on panel CKZ1GFSJ   *
    *                      to create the source and target jobs,   *
    *                      the following message is displayed and  *
    *                      one is returned to panel CKZ1BDCJ.      *
    *                      "CKZ414E - The                          *
    *                      TARGET-JOB-INDEX-REBUILD-DDN value must *
    *                      be provided in the COPY command when    *
    *                      REBUILD-INDEXES-EXECUTE is set          *
    *                      to "YES" in the SET command".           *
    *                      TARGET-JOB-INDEX-REBUILD-DDN  is NOT    *
    *                      required for REBUILD-INDEX-EXECUTE YES. *
    *                      No job template is used by this         *
    *                      process therefore no DDName is          *
    *                      required.                               *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI47900

  • Reported component name

    DB2 CLONING TOO

  • Reported component ID

    5655N1000

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-08-31

  • Closed date

    2015-09-14

  • Last modified date

    2015-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI31105

Modules/Macros

  •    CKZ2ADFN CKZ2CLON CKZ2DAPS CKZ2DBSS CKZ2DSCC
    CKZ2DSCS CKZ2EDDS CKZ2ETCP CKZ2MAIN CKZ2PARM CKZ2PRDM CKZ2RFDT
    CKZ2SSSJ CKZ2TCOP CKZ2TDDF CKZ2TJCL CKZ2TSET CKZ4ASYS CKZ4RDLL
    

Fix information

  • Fixed component name

    DB2 CLONING TOO

  • Fixed component ID

    5655N1000

Applicable component levels

  • R310 PSY UI31105

       UP15/09/22 P F509

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: