Error description

  • Customer code calling the ESM Task Start API would fail with
    the return/reason code indicating that no UOW could be
    found to start. An examination of ESM via SMOF clearly shows
    that the UOWs are on the Ready Queue awaiting to be started.
    

Local fix

  • Start task manually
    

Problem summary

  • -
    

Problem conclusion

  • PI47844 - USERS AFFECTED - ALL ESM.
              This APAR corrects an issue where the TASK START API
              failed to start its requested task(s) due to
              encountering a bad WRB (Work Request Block) which had
              a null FUOW (Functional Unit Of Work) pointer.
              With this fix on, the TASK START API will note the
              error and continue down the entire WRB list starting
              any matching task/UOW combinations.
                                                    (P20057)
    
    DOCUMENTATION:
    NOTED BELOW ARE DOCUMENTATION CHANGES INCLUDED IN THIS APA
       DOCUMENT .......... ESM V1R3 User's Guide
       DOCUMENT NUMBER ... SC31-4635-01
       CHAPTER AND PAGE .. Messages and Codes
       CHANGE ............ Add the following message:
    
       DKNSMSRV16 - TASK NOT STARTED DUE TO MISSING FUOW
    
       This message indicates that a bad Task Work Request
       Block or WRB was encountered during a Task Start API call.
       The bad WRB has no FUOW pointer. It doesn't point to a
       Unit of Work or string.
    
       This message only appears as a WTO if this condition
       occurred but other matching tasks in the WRB list have
       been successfully started. Corresponding trace information
       for the error is also written to the ESM log under
       TSKSTX16.
    
       Operator action: None
    
       Supervisor action: The supervisor should check the ESM log
       for the TSKSTX16 trace entry. Field INFIELDs will show the
       Task/Version and UOW information which had this error.
    
       The supervisor should then verify in SMOF that all such
       tasks were indeed started. If not, then a manual start
       may be needed.
    
    ACTION:
          FOR THIS APAR TO BECOME EFFECTIVE, FOLLOW THESE STEPS.
          1. APPLY APAR WITH SMP/E.
          2. RESTART CPCS.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI47844

  • Reported component name

    ENHANCED SYS. M

  • Reported component ID

    5799ESM00

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-08-28

  • Closed date

    2016-02-22

  • Last modified date

    2016-03-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI35561

Modules/Macros

  • DKNSMSRV
    

Publications Referenced
SC31463501    

Fix information

  • Fixed component name

    ENHANCED SYS. M

  • Fixed component ID

    5799ESM00

Applicable component levels

  • R130 PSY UI35561

       UP16/03/01 P F602

Fix is available