  • Closed as program error.

Error description

  • During the upgrade process, Installation Manager fails with
    error CRIMA1217E indicating that a problem happened in the
    post-install.xml script during the uninstall phase of
    Worklight V6.0.
    The corresponding worklight-uninstall.log file in the
    Installation Manager logs directory reveals that a wrong
    Deployment Manager (Dmgr02) was attempted to be started instead
    of the expected one (Dmgr01).
    
    Excerpt of the trace
         [java] call-wsadmin-callee:
         [java]      [echo] ADMU0116I: Tool information is being
    logged in file
         [java]      [echo]            C:\Program
    Files\IBM\WebSphere\AppServerND\profiles\Dmgr01\logs\dmgr\server
    Status.log
         [java]      [echo] ADMU0128I: Starting tool with the Dmgr01
    profile
         [java]      [echo] ADMU0500I: Retrieving server status for
    dmgr
         [java]      [echo] ADMU0509I: The Deployment Manager "dmgr"
    cannot be reached. It appears to be
         [java]      [echo]            stopped.
         [java]      [echo] ADMU0116I: Tool information is being
    logged in file
         [java]      [echo]            C:\Program
    Files\IBM\WebSphere\AppServerND\profiles\Dmgr02\logs\dmgr\startS
    erver.log
         [java]      [echo] ADMU3027E: An instance of the server may
    already be running
         [java]      [echo]            : dmgr
         [java]      [exec] Result: 2
         [java]
         [java] BUILD FAILED
         [java]
    C:\Users\IBM_ADMIN\IBM\Worklight_6002\WorklightServer\post-insta
    ll.xml:4712: startManager failed.
    

Local fix

  • Start the deployment manager of the cell where Application
    Center was deployed before proceeding to the upgrade with
    Installation Manager.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users who installed WebSphere Application Server Network     *
    * Deployment (WAS ND) with several Deployment Managers on the  *
    * same machines and who are trying to upgrade IBM Application  *
    * Center using Installation Manager.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When IBM Application Center V6.0.x is deployed on a WAS ND   *
    * configuration managed by a Deployment Manager that is not    *
    * the default then the upgrade may fail if this Deployment     *
    * Manager is not started during the upgrade process. The code  *
    * of the upgrade process only handles the default WAS ND       *
    * Deployment Manager.                                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • A validation was added to the code to select and start the
    correct WAS ND Deployment Manager before performing the upgrade.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI46504

  • Reported component name

    MFPF/WORKLIGHT

  • Reported component ID

    5725I4301

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-08-07

  • Closed date

    2015-09-14

  • Last modified date

    2015-09-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MFPF/WORKLIGHT

  • Fixed component ID

    5725I4301

Applicable component levels

  • R600 PSY

       UP