PI45618: IF THE WAS SSL CONFIGURATION SUPPORTS ONLY TLS V1.1 OR TLS V1.2 THE RUNTIME SYNCHRONIZATION FAILS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When in the WAS cell the SSL configuration supports only the
    protocols TLS V1.1 or TLS V1.2 the MFP runtime fails to
    initialize because when it pings the admin services the protocol
    TLS V1 is always used.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Worklight administration users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When in a WAS cell the SSL configuration supports only the   *
    * protocols TLS V1.1 or TLS V1.2 the MFP runtime fails to      *
    * initialize when the administration services endpoint         *
    * protocol is SSL because when the runtime pings the admin     *
    * services endpoint the protocol TLS V1 is always used.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • The runtime synchronization leverages the WebSphere SSL
    configuration.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI45618

  • Reported component name

    MFPF/WORKLIGHT

  • Reported component ID

    5725I4301

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-07-24

  • Closed date

    2015-08-19

  • Last modified date

    2015-08-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MFPF/WORKLIGHT

  • Fixed component ID

    5725I4301

Applicable component levels

  • R620 PSY

       UP

  • R630 PSY

       UP

  • R700 PSY

       UP

  • R710 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021