Fixes are available
APAR status
Closed as program error.
Error description
When in the WAS cell the SSL configuration supports only the protocols TLS V1.1 or TLS V1.2 the MFP runtime fails to initialize because when it pings the admin services the protocol TLS V1 is always used.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Worklight administration users. * **************************************************************** * PROBLEM DESCRIPTION: * * When in a WAS cell the SSL configuration supports only the * * protocols TLS V1.1 or TLS V1.2 the MFP runtime fails to * * initialize when the administration services endpoint * * protocol is SSL because when the runtime pings the admin * * services endpoint the protocol TLS V1 is always used. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The runtime synchronization leverages the WebSphere SSL configuration.
Temporary fix
Comments
APAR Information
APAR number
PI45618
Reported component name
MFPF/WORKLIGHT
Reported component ID
5725I4301
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-07-24
Closed date
2015-08-19
Last modified date
2015-08-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MFPF/WORKLIGHT
Fixed component ID
5725I4301
Applicable component levels
R620 PSY
UP
R630 PSY
UP
R700 PSY
UP
R710 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: