IBM Support

PI45297: MVS SETXCF COUPLE,PSWITCH,TYPE=LOGR GETS ERROR IXC248E

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer issued command:
    MVS SETXCF COUPLE,PSWITCH,TYPE=LOGR
    -
    The Primary and Alternate CDS (Couple Dataset) need to be in
    sync before the PSWITCH can be issued. To confirm this,
    customers can enter command D XCF,CPL,TYPE=LOGR. If the CDS
    datasets are not in sync, the following error message is
    issued:
    IXC248E COUPLE DATA SET
    SYS1.hlqPLEX.SFM.CDSP ON VOLSER xxxxxx
    FOR SFM MAY BE IN USE BY ANOTHER SYSPLEX.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: GDPS SYSPLEX CDS MANAGEMENT                  *
    *                 GDPS/PPRC GDPS/PPRC HM GDPS/MTMM             *
    ****************************************************************
    * PROBLEM DESCRIPTION: On GDPS Sysplex CDS management command  *
    *                      MVS SETXCF COUPLE,PSWITCH,TYPE=XXX      *
    *                      following message is received:          *
    *                      IXC386I SETXCF COUPLE,PSWITCH REQUIRES  *
    *                      A SYNCHRONIZED ALTERNATE COUPLE DATA    *
    *                      SET FOR CDS_Type                        *
    *                      GDPS CDS management action returns      *
    *                      FAILED status.                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When GDPS Sysplex CDS management issues command
    SETXCF COUPLE,PSWITCH,TYPE=XXX
    The Primary and Alternate CDS (Couple Dataset) need to be in
    sync before the PSWITCH can be issued.
    If the CDS datasets are not in sync, the following error
    message is issued on command D XCF,CPL,TYPE=CDS_Type.
    IXC248E COUPLE DATA SET SYS1.hlqPLEX.SFM.CDS_Type
    ON VOLSER xxxxxx FOR SFM MAY BE IN USE BY ANOTHER SYSPLEX.
    If PSWITCH command is issued too early in GDPS CDS management
    scenario, the following message is returned:
    IXC386I SETXCF COUPLE,PSWITCH REQUIRES A SYNCHRONIZED
    ALTERNATE COUPLE DATA SET FOR CDS_Type
    

Problem conclusion

  • GDPS code has been changed to check and analyse CDS status
    before issuing SETXCF PSWITCH command.
    GDPSPPRC/K
    GDPSPPRCHM/K
    GDPSMTMM/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI45297

  • Reported component name

    GDPS-GEO DISP P

  • Reported component ID

    694235B00

  • Reported release

    3BC

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-07-20

  • Closed date

    2015-10-02

  • Last modified date

    2015-11-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI31706 UI31707

Modules/Macros

  • VPCESPM2 VPCESPM3
    

Fix information

  • Fixed component name

    GDPS-GEO DISP P

  • Fixed component ID

    694235B00

Applicable component levels

  • R3BC PSY UI31706

       UP15/10/06 P F510

  • R3CC PSY UI31707

       UP15/10/06 P F510

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3BC","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: