A fix is available
APAR status
Closed as program error.
Error description
If the customer imports classes that exist in the <project>/server/lib folder in one of their Java adapter classes, that adapter will fail to compile as it will not be able to resolve the imported class. The reason is that <project>/server/lib is not on the classpath when compiling Java adapters.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM MobileFirst Platform Foundation developers building Java * * adapters using IBM MobileFirst Platform Foundatoin Studio or * * the Command Line Interface * **************************************************************** * PROBLEM DESCRIPTION: * * Java adapters which import classes defined in a JAR file in * * the <project>/server/lib folder will not compile. The * * compilation error will be that the class defined in the JAR * * file cannot be resolved. The underlying reason for this is * * that JAR files placed in <project>/server/lib are not on the * * classpath when compiling Java adapters. * **************************************************************** * RECOMMENDATION: * * NONE * ****************************************************************
Problem conclusion
The fix ensures that JAR files placed in <project>/server/lib are automatically on the classpath when compiling Java adapters using MobileFirst Studio or the Command Line Interface.
Temporary fix
Comments
APAR Information
APAR number
PI45283
Reported component name
MFPF/WORKLIGHT
Reported component ID
5725I4301
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-07-20
Closed date
2015-07-23
Last modified date
2015-07-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MFPF/WORKLIGHT
Fixed component ID
5725I4301
Applicable component levels
R700 PSY
UP