A fix is available
APAR status
Closed as program error.
Error description
IGYIN5295-U The compilation failed due to an internal error detected in the compiler back-end" when using OPT(1) and ADATA
Local fix
Dont use ADATA.
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5.2 using both the * * ADATA and OPT(1|2) compiler options when * * compiling COBOL programs that result in * * messages being written during the * * optimization or code generation phases * * (e.g., unreachable code message). * * * **************************************************************** * PROBLEM DESCRIPTION: Compiler abend with the following * * messages: * * * * IGYIN5125-U The compilation was * * terminated due to a compiler error in * * phase id . * * * * IGYIN5295-U The compilation failed * * due to an internal error detected in * * the compiler back-end. The error code * * was 267. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** While writing messages during the optimization phase, the compiler accessed an ADATA-related structure that is not available during that phase of compilation.
Problem conclusion
The compiler was updated so that messages can be successfully written during the optimization phase or code generation phase, even when the ADATA compiler option is used. Apply provided service.
Temporary fix
Comments
APAR Information
APAR number
PI44915
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-07-14
Closed date
2015-07-23
Last modified date
2015-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI29671 UI29673 UI29672 UI29674
Modules/Macros
IGYACT IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$D IGYCEN$R IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCFGEN IGYCFREE IGYCINIT IGYCJA$D IGYCJA$R IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCKACT IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$D IGYCUE$R IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCXREF IGYECWI IGYJNI IGYMAKEF IGYMSGE IGYMSGK IGYMSGT IGYTACTC IGY8RWTU
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R52H PSY UI29672
UP15/08/04 P F508
R520 PSY UI29671
UP15/08/04 P F508
R521 PSY UI29673
UP15/08/04 P F508
R522 PSY UI29674
UP15/08/04 P F508
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 September 2015