IBM Support

PI44227: A WORKLIGHT ADAPTER CALL FAILS WITH AN ERROR INDICATING THAT THERE WAS A FAILURE TO PARSE THE JSON STRING.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An adapter call fails with the following error:
    
    FWLSE0101E: Caused by:  [project qa]java.io.IOException:
    Unexpectedcharacter '<' on line 1, column 1
    java.lang.RuntimeException: Failed to parse JSON string
    
    The string in the message is in XML format.  However, this
    issue occurs if the response contains 0E+0.  If the value
    resolves to non-zero, the failure does not occur.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Customers with adapters that receive number values from the  *
    * backend in format 0E+0                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Adapter code failed to parse 0E+0 as a number.               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • Pre-parsing was done in witch 0E+0 was replaced with 0.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI44227

  • Reported component name

    MFPF/WORKLIGHT

  • Reported component ID

    5725I4301

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-07-02

  • Closed date

    2015-07-15

  • Last modified date

    2015-07-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MFPF/WORKLIGHT

  • Fixed component ID

    5725I4301

Applicable component levels

  • R610 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: