Error description

  • Message IRT273E contains incorrect abend and return code.
    Additionally, customers should be informed that if
    STEPLIB/JOBLIB is authorized, and the application load library
    is also authorized, the IRTOPT library pointed to by the
    IRT#OPT member must also be authorized.  If not, message
    IRT273E is issued followed by ABENDU4000.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Program Restart Facility V2R2.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message IRT273E contains incorrect      *
    *                      abend and return code.                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Message IRT273E contains incorrect abend and return code.
    Additionally, customers should be informed that if
    STEPLIB/JOBLIB is authorized, and the application load library
    is also authorized, the IRTOPT library pointed to by the
    IRT#OPT member must also be authorized.  If not, message
    IRT273E is issued followed by ABENDU4000.
    

Problem conclusion

  • Code has been modified to correct message IRT273E
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI43925

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-06-26

  • Closed date

    2016-03-09

  • Last modified date

    2016-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI36000

Modules/Macros

  •    IRTOPTR
    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R220 PSY UI36000

       UP16/03/21 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSV7D2","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
14 December 2020