A fix is available
APAR status
Closed as program error.
Error description
Ading explicit close for Accounting File at program termination to avoid ABEND CODE=C03
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: 1. OMPE Batch Accounting File job may * * fail during termination with ABENDC03 * * when FILE is allocated to TAPE device. * * * * 2. OMPE Batch Accounting Reduce / Save * * job may run long time to complete on a * * big amount of input data. * * * * 3. OMPE Batch SQLACTIVITY Report job * * may encounter ABEND0C4 on DB2 V10 * * IFCID 96 processing after FPEC4030W * * message(s) has been issued. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: 1. ABENDC03 with Accounting File allocated to Tape can be encountered because File was not closed explicitly before control returned to z/OS. Explicit Accounting File Close added to fix this possible issue. 2. Not necessary data store reclaim actions at the end of Batch Accounting Reduce / Save job may take considerable time and CPU. These actions are now eliminated to reduce CPU and elapsed time. 3. Invalid DB2 V10 supplied QW0096PC_Off field value may cause memory corruption to occur with subsequent ABEND0C4 in OMPE Batch SQLACTIVITY Report job after one or more FPEC4030W warning messages issued. OMPE Batch code changed to tolerate invalid QW0096PC_Off value without getting an ABEND0C4. PROBLEM CONCLUSION: Code changed to fix described above problems. KEYWORDS: BATCH ACCOUNTING FILE ABENDC03 SQLACTIVITY ABEND0C4
Problem conclusion
Code changed to fix described above problems.
Temporary fix
Comments
APAR Information
APAR number
PI42811
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-11
Closed date
2015-09-07
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI30911 UI30912 UI30913 UI30914
Modules/Macros
DGOAFILE DGOAZREC DGOAZREP FPEUIFCI FPEUIFC2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UI30911
UP15/10/02 P F509
R511 PSY UI30912
UP15/10/02 P F509
R520 PSY UI30913
UP15/10/02 P F509
R530 PSY UI30914
UP15/10/02 P F509
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]