Fixes are available
APAR status
Closed as program error.
Error description
An error is observed with generated Java when returning dates between 1966 and 1979 with Italian daylight savings time applied due to the ICU release. For example applying the date 23/05/1971 where the timezone is added as a JVM argument within the Run Configuration in the VM arguments as -Duser.timezone=Europe/Rome the following error will then occur with both the EGL debugger and via the Java program: (16:09:30> EGL0102E The 23/05/1971 value of string type cannot be converted to the date type. (16:09:30> EGL0002I The error occurred in testcase processing the main function. (16:09:30> endRunUnit testcase (error termination) with returnCode=693 EGL0102E The 23/05/1971 value of string type cannot be converted to the date type. EGL0002I The error occurred in testcase processing the main function.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * EGL Java user in Italian timezone and use date variable. * **************************************************************** * PROBLEM DESCRIPTION: * * A runtime error is observed with EGL Java when returning * * dates between 1966 and 1979 with Italian daylight savings * * time. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The problem is fixed.
Temporary fix
Comments
APAR Information
APAR number
PI42003
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
911
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-05-29
Closed date
2016-04-05
Last modified date
2016-04-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSY
UP
R911 PSY
UP
R950 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMQ79","label":"Rational Business Developer"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.1.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: