IBM Support

PI40739: CHANGE DEFAULT VALUE FOR PIPEWAIT CONTROL STATEMENT. USER CAN ADD PIPEWAIT STATEMENT TO INSTALLATION DEFAULT OPTION TABLE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • This APAR enables Smart Reorg utility to change the default
    value for the PIPEWAIT control statement. User can add the
    PIPEWAIT statement to the Installation Default Option Table.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS Database Reorganization     *
    *                 Expert for z/OS Version 4 Release 1          *
    *                 (FMID=H25N410)                               *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR enables the Smart Reorg       *
    *                      utility to change the default value     *
    *                      for the PIPEWAIT control statement.     *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR enables the Smart Reorg utility to change the default
    value for the PIPEWAIT control statement.
    
    If "PIPEWAIT=15" is coded in the HPSCOPT statements
    for creating an Installation Default Option Table (HPSCOPTI)
    as below, the maximum wait time is 15 minutes and it is applied
    for the both states; the open wait state (OPEN) and the read
    and write wait state (RDWR) of each PIPE ID.
       HPSCOPT START
       HPSCOPT DRIVER,PIPEWAIT=15
       HPSCOPT END
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IBM IMS Database Reorganization Expert for z/OS User's
    Guide Version 4 Release 1 Suffix 3 (SC19-1137-04) should be
    changed as follows:
    ---------------------------------------------------------------
    > Reorganizing a database in one job step
    >> Smart Reorg JCL statements
    >>> Control statements for the Smart Reorg utility
    >>>> Control statements for the Smart Reorg Driver
    >>>>> PIPEWAIT control statement
    
     PIPEWAIT control statement
    
      Specifies the amount of time a writer or a reader of a pipe
      can remain in a wait state before the Smart Reorg Driver
      issues a message and abends.
    
     +-------------------------------------------------------------+
     |                           +--,1--+                          |
     | >>---PIPEWAIT=--+-(-time--+------+--)-+-+-------------+-->< |
     |                 |         +--,2--+    | +-+-,RDWR--+--+     |
     |                 +-time----------------+   +-,OPEN--+        |
     +-------------------------------------------------------------+
    
      :
      The default time value is 15 (minutes) for each pipe
      when the data is read from or written to the pipe,
      and is 0.5 minutes when a reader or writer task waits for
      the partner task to open the pipe.
    
    | Tip: You can change the default value of this control
    | statement by creating an Installation Default Option Table.
    | For more information, see Setting installation default
    | options.
    ---------------------------------------------------------------
    > Reference
    >> Setting installation default options
    >>> How to code HPSCOPT macro statements
    
     ____________________________________________________________
     |                                                           |
     | DRIVER                                                    |
     |                                                           |
     |             .-,-----------------------------------.       |
     |             V                                     |       |
     | |--DRIVER---+---------------------------------+---------| |
     |             :                                 :           |
    ||             |                                 |           |
    ||             +-PIPEWATT= time -----------------|           |
     |             :                                 :           |
     |___________________________________________________________|
    
    
      The identifier of each utility and the option keywords that
       are supported by the utility are as follows:
    
     DRIVER
        This parameter identifies the Smart Reorg Driver (HPSGMAIN).
        This parameter supports the following values:
        -   CONDREORG
        :
    |   -   PIPEWAIT (*)
        :
    
    |  The time value specified for the PIPEWAIT option is applied
    |  for both states; the open wait state (OPEN) and
    |  the read and write wait state (RDWR), for each PIPE.
    ---------------------------------------------------------------
    ================ End of Documentation Change ==================
    

APAR Information

  • APAR number

    PI40739

  • Reported component name

    IMS DB REORG EX

  • Reported component ID

    5655F7400

  • Reported release

    410

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2015-05-08

  • Closed date

    2015-05-14

  • Last modified date

    2015-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI27649

Modules/Macros

  • HPSCOPT  HPSCOPTS HPSGCM00 HPSGOPTG
    

Publications Referenced
SC19113704    

Fix information

  • Fixed component name

    IMS DB REORG EX

  • Fixed component ID

    5655F7400

Applicable component levels

  • R410 PSY UI27649

       UP15/05/16 P F505

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVL5Q","label":"IMS Database Reorganization Expert for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: