IBM Support

PI40707: OMPE CLASSIC R.C.A LOOPING

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Some corrections must be performed in OmPE for calculation and
    reseting RC/RS before the retry cycle
    
    Panel ZEDSN
    Navigation from ZMENU select R  RESOURCE MANAGERS
    From ZRMMENU select C  EDM POOL
    From ZEDMP take option A-EDM POOL SNAPSHOT
    
    FPEV0162W  TRACES ARE STARTED FOR FURTHER ANALYSIS OF HIGH
    SUBTASK USAGE
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Selecting EDM POOL SNAPSHOT SUMMARY     *
    *                      (option R.C.A) from the Classic         *
    *                      Interface does not return data.         *
    *                      The CPU consumption of the OMEGAMON     *
    *                      Collector started task increases.       *
    *                      PE Server detects high CPU for subtask  *
    *                      FPEVDB2I, issues message FPEV0158W, and *
    *                      starts the PE Server traces.            *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    When the Classic Interface requests EDM POOL SNAPSHOT SUMMARY
    data from PE Server and the size of the provided data buffer
    is not large enough to store the available data, PE Server
    returns the request indicating data truncation. The display
    logic re-allocates a larger buffer and repeats the request
    without clearing the attributes indicating data truncation.
    Depending on the data volume available on PE Server side this
    may result in a loop causing high CPU in the DB2 interface
    task FPEVDB2I.
    
    PROBLEM CONCLUSION:
    The code has been corrected accordingly.
    
    KEYWORDS:
    EDM POOL SNAPSHOT SUMMARY HIGH CPU FPEV0158W
    

Problem conclusion

  • The code has been corrected accordingly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI40707

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-05-11

  • Closed date

    2015-06-22

  • Last modified date

    2017-01-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI28691 UI28692 PI50908

Modules/Macros

  •    DGOVISI  DGOVMSTR FPEVDB2I KO2CCAFB
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R520 PSY UI28691

       UP15/06/23 P F506

  • R530 PSY UI28692

       UP15/06/23 P F506

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
26 January 2017