Error description
MSGIPI0424E error message in submitting an IMS Connect Report when Preferred Date Format US or European is selected in the dialog. Error received was displayed as: IPI0424E Command error ***** START DATE field has invalid format, Digit, or Value FROM(05/03/2015,
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.4 * **************************************************************** * PROBLEM DESCRIPTION: Error IPI0424E when submitting an IMS * * Connect Report when Preferred Date * * Format US or European is selected in * * the dialog. * **************************************************************** * RECOMMENDATION: * **************************************************************** Error IPI0424E when submitting an IMS Connect Report when Preferred Date Format US or European is selected in the dialog.
Problem conclusion
The IMS PA batch processor expects all Dates to be in the default Sorting format (i.e. YYYY/MM/DD), the dialog allows for a Preferred Date Format other than Sorting of either US or European During JCL creation for an IMS Connect Report any From/To dates specified in the Report Set should be re- formatted if either the US or European Date Formats have been selected. The specified Date Format was not being checked, and all dates assumed to be in the default Sorting format resulting in an invalid date being passed to the batch processor and receiving the IPI0424E error. This change ensures that the specified Date Format is checked and dates are converted to the Sorting format as required by the batch processor.
Temporary fix
Comments
APAR Information
APAR number
PI40455
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
440
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-05-05
Closed date
2015-05-13
Last modified date
2015-09-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IPISAPAR IPIZDCXG IPIZSCEX IPIZXDRV
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R440 PSY UI27576
UP15/05/15 P F505