Error description
Rational Developer for System z - RDz - v9.1.1 Description : This occurs in case of Cobol program with copybooks associated. On RDz 8.5.1.5, there was an error marker on "ROLLBACK", which was used in a main program as a variable as shown below : 088890 CLOTURE. 088900 IF ROLL-A-FAIRE-BIS = 1 088910* MOVE 1 TO ROLL-A-FAIRE 088920 SET ROLLBACK TO TRUE 088930 END-IF The ROLLBACK variable is defined in the copybooks : * LE ROLLBACK 00300001 * 0 PAS DE ROLLBACK A FAIRE 00310001 * 1 ROLLBACK A FAIRE 00320001 15 PRJ024-SIGNA-ROLLBACK PIC X. 00330001 88 PRJ024-ROOLBACK-A-FAIRE VALUE '1'. 00340001 This seems to be a bug in the RDz parser, since this file was compiled successfully by the Cobol compiler. But on RDz 9.1.1, there is no more error marker. The parser just silently fails and all syntax functions are disabled. The only way to get more information on this error on RDz 9.1.1 was to go to the preferences, and in the Tracing page enable the FINEST trace on com.ibm.systemz.common.editor. It shows there is an IndexOutOfBoundsException in the parser : java.lang.IndexOutOfBoundsException: Index: 59631, Size: 24105 This issue seems to happen on programs containing a "REPLACE" statement. Steps to have the error message : - In the preferences, put FINEST level in com.ibm.systemz.cobol.editor.core + com.ibm.systemz.cobol.editor.lpex + com.ibm.systemz.common.editor. - Open the program from the z/OS project perspective (tested with both Cobol and LPEX editors) - Await for the copybooks download - Got the red cross over the suitcase icon at the bottom right of the screen and "Tooling failed to initialize dur to syntax error -> when adding syntax check errors, they are not detected.
Local fix
No
Problem summary
COBOL parser incorrectly calculated offsets when processing REPLACE statements.
Problem conclusion
Fixed offset calculation for processing REPLACE statements in COBOL parser.
Temporary fix
Comments
APAR Information
APAR number
PI39800
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
911
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-04-24
Closed date
2015-10-16
Last modified date
2015-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R911 PSY
UP
Document Information
Modified date:
16 October 2021