IBM Support

PI39673: ONE TIME DB2 ABEND 0CX ON DSNIDM.DSNB1GET+0014 DURING STARTUP ORONE TIME DB2 ABEND 0CX NEAR DSNXGRDS.DSNXEDSC+0030 AFTER SHUTDOW

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Small thread ABEND exposure in DSNB1GET+14 after CQM installs.
    
    
    This APAR installs the object collection routine in an area that
    is not subject to interrupts.
    

Local fix

  • The exposure is very small, but to reduce exposure, start CQM
    during a period of little or no thread activity.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of DB2 Query Monitor.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Small thread ABEND exposure in          *
    *                      DSNB1GET+14 after CQM installs. This    *
    *                      APAR installs the object collection     *
    *                      routine in an area that is not subject  *
    *                      to interrupts.                          *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    Code has been changed to correct this condition.
    

Problem conclusion

  • APPLY the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI39673

  • Reported component name

    DB2 QUERY MONIT

  • Reported component ID

    5655E6701

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-04-22

  • Closed date

    2015-07-09

  • Last modified date

    2015-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI29248 UI29249

Modules/Macros

  • CQMMINST CQMOXGAX CQMOXGBX CQMTEDA1
    

Fix information

  • Fixed component name

    DB2 QUERY MONIT

  • Fixed component ID

    5655E6701

Applicable component levels

  • R310 PSY UI29248

       UP15/07/29 P F507

  • R320 PSY UI29249

       UP15/07/29 P F507

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0"}]

Document Information

Modified date:
17 March 2021