APAR status
Closed as program error.
Error description
When attempting to synchronize with a BusinessWorks (BW) project with TIBCO Runtime Architecture (TRA) 5.9 you see the following error message: An internal error occurred during: "SyncWorker" The JVM console shows the following: java.lang.NoClassDefFoundError: org.w3c.dom.ElementTraversal at java.lang.ClassLoader.defineClassImpl(Native Method) at java.lang.ClassLoader.defineClass(ClassLoader.java:306) at org.eclipse.osgi.internal.baseadaptor.DefaultClassLoader.defineC lass(DefaultClassLoader.java:188) at org.eclipse.osgi.baseadaptor.loader.ClasspathManager.defineClass HoldingLock(ClasspathManager.java:632) at org.eclipse.osgi.baseadaptor.loader.ClasspathManager.defineClass (ClasspathManager.java:607) WORKAROUND: Add the file xml-apis.jar to your Library Manager TIBCO BusinessWorks configuration. On Windows this is typically found at: C:\tibco\tpcl\5.9\lib\xml-apis.jar. Note that jakarta-regexp-1.2.jar has moved location. On Windows it is typically at: C:\tibco\tpcl\5.9\lib\jakarta-regexp-1.2.jar
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with TIBCO * * BW 5.12 * **************************************************************** * PROBLEM DESCRIPTION: * * TIBCO BUSINESSWORKS SYNCHRONIZATION FAILS WITH "SYNCWORKER" * * ERROR * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v8.7.1.1 which * * includes a fix for this issue * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 8.7.1.1 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI38623
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-04-08
Closed date
2016-01-07
Last modified date
2016-01-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"IBM Rational Test Workbench"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]