IBM Support

PI38413: OBJECTS INCORRECTLY EXCLUDED FROM UTILITY BUILD

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Specifying wild-carded objects, some of which are created with
    DEFINE NO and are not yet physically created, can cause
    Automation Tool to exclude other eligible objects from
    processing.  There may be no message in the build job indicating
    the objects that are incorrectly excluded.  If the build is run
    with DEBUG_MODE set to ON, the following message can be seen for
    the incorrectly excluded objects:
    HAA#OBEX - DELETING TS dbname tsname
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM DB2 Automation Tool             *
    ****************************************************************
    * PROBLEM DESCRIPTION: Specifying wild-carded objects, some of *
    *                      which are created with DEFINE NO and    *
    *                      are not yet physically created, can     *
    *                      cause Automation Tool to exclude other  *
    *                      eligible objects from processing.       *
    *                      There may be no message in the build    *
    *                      job indicating the objects that are     *
    *                      incorrectly excluded.  If the build     *
    *                      is run with DEBUG_MODE set to ON, the   *
    *                      following message can be seen for       *
    *                      the incorrectly excluded objects:       *
    *                      HAA#OBEX - DELETING TS dbname tsname    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Apply the PTF.
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PI38413

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-04-03

  • Closed date

    2015-04-17

  • Last modified date

    2015-05-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI26838

Modules/Macros

  • HAA#OBEX
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R410 PSY UI26838

       UP15/04/22 P F504

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUWB","label":"IBM Db2 Automation Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: