A fix is available
APAR status
Closed as program error.
Error description
ICAT conversion generates KD2_PFnn_HIS_WHEN_* parms with embedded blanks that are not the same as null values. These parms values: KD2_PF01_HIS_WHEN_AUTHID " " KD2_PF01_HIS_WHEN_CONNID " " KD2_PF01_HIS_WHEN_CORRID " " KD2_PF01_HIS_WHEN_ORIG " " KD2_PF01_HIS_WHEN_PLAN " " . The same vales carry forward to PARMGEN conversion and treated differently than a true null. Because of this, NTH will not come up. The following error messages appear when starting STC: KO2H1367E ssid NEAR-TERM HISTORY DATA COLLECTOR - INSUFFICIENT PARMS IN THIS RKANPAR RECORD: KO2H1373E ssid NEAR-TERM HISTORY DATA COLLECTOR - AUTH( ) KO2O1307I NEAR-TERM HISTORY DATA COLLECTOR IS TERMINATING (H2INITE ) .
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - NTH - Near Term History * **************************************************************** * PROBLEM DESCRIPTION: EMPTY PARAMETERS IN COPTXXXX RKD2PAR * * MEMBER FORCE NTH TO STOP. * * CAN BE CAUSED BY KD2_PFNN_HIS_WHEN_* * * PARMS WITH EMBEDDED BLANKS. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Any keyword, specified in the COPTxxxx member without a parameter like INTERVAL(), forces Near Term History to stop with messages KO2H1367E, KO2H1373E. PROBLEM CONCLUSION: Change logic to process keywords without parameters correctly by setting default values (where it is possible) or special processing. KEYWORDS: NTH NEAR TERM HISTORY KO2H1367E KO2H1373E PARMGEN ICAT KD2_PFNN_HIS_WHEN_* PARMS WITH EMBEDDED BLANKS
Problem conclusion
Change logic to process keywords without parameters correctly by setting default values (where it is possible) or special processing.
Temporary fix
Comments
APAR Information
APAR number
PI37768
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-25
Closed date
2015-08-20
Last modified date
2017-01-26
APAR is sysrouted FROM one or more of the following:
PI37452
APAR is sysrouted TO one or more of the following:
UI30356 UI30357 UI30358
Modules/Macros
KO2HPR1B KO2HPR2B
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R511 PSY UI30356
UP15/08/23 P F508
R520 PSY UI30357
UP15/08/23 P F508
R530 PSY UI30358
UP15/08/23 P F508
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: