A fix is available
APAR status
Closed as program error.
Error description
The following abend may occur sporadically when navigating through Distributed Thread Detail screens/workspaces in E3270/TEP : KO2I0170U S0C4 ABEND IN MODULE KO2CAPIK PERCOLATED TO D5API MODULE KO2ACONB DUMPID=006 REQUESTED BY JOB (OMDM111 ) DUMP TITLE=OMEGAMON II FOR DB2: COMPID=5655OPE00, JOB=OMDM111 , LMOD=KO2CAPIK#L, CSECT=#UNKNOWN, OFFSET=003184 IEA043I SVC DUMP REACHED MAXSPACE LIMIT - MAXSPACE=00010000 MEG IEA794I SVC DUMP HAS CAPTURED: 571 DUMPID=007 REQUESTED BY JOB (OMDM111 ) DUMP TITLE=OMEGAMON II FOR DB2 DUMP: TASK=COMMCOLL,ID=V520 ,MOD=KO2CAPIK,OFFSET=003184,CODE=S0C4/00000010
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - D5API * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: Unexpected code path could lead to * * unbounded loop while reading data. * * This loop will quickly abend0C4. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Abend S0C4 in module KO2CAPIK percolated to D5API module KO2ACONB. PROBLEM CONCLUSION: Code was changed to correct code path. KEYWORDS: D5API ABEND 0C4 PI15395
Problem conclusion
Code was changed to correct code path.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
PI37342
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-20
Closed date
2015-06-02
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI28141
Modules/Macros
KO2APCPA KO2APCPK KO2APCPS KO2APCQA KO2APCQK KO2APCQS KO2APC1A KO2APC1K KO2APC1S KO2APC3A KO2APC3K KO2APC3S KO2CIFCB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R520 PSY UI28141
UP15/06/04 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]