A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 in BTSDBS00 when using PRF and BTS. PRF does not propogate the BTS main control block BTSCOMM address.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users of Program Restart Facility V2R2 * **************************************************************** * PROBLEM DESCRIPTION: PRF causes an S0C4 abend in IMS Batch * * Terminal Simulator module BTSPC000 * * because PRF does not propagate the BTS * * ECB used by BTS when it attaches the * * IMS Region Controller DFSRRC00. * **************************************************************** * RECOMMENDATION: Apply the PTF that corrects this APAR. * **************************************************************** PRF now saves the BTS ECB on entry to IRTUPX00, the PRF hook in the IMS Region Controller. PRF passes the ECB to the BTS application BTSPC000 when it is attached to by IRTRCC00.
Problem conclusion
The abend S0C4 no longer occurs because BTSPC000 receives the correct ECB address.
Temporary fix
Comments
APAR Information
APAR number
PI37125
Reported component name
IMS PGM RESTART
Reported component ID
5655E1400
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-16
Closed date
2015-04-08
Last modified date
2015-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI26613
Modules/Macros
IRTRCC00 IRTUPX00
Fix information
Fixed component name
IMS PGM RESTART
Fixed component ID
5655E1400
Applicable component levels
R220 PSY UI26613
UP15/04/20 P F504
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
24 January 2022