PI36446: HPIC MAINTENANCE FOR FABJRCH3 IS NOT APPLIED CORRECTLY, THEN HPIC ABEND S0C1 ( ABEND0C1 ) 15/03/12 PTF PECHANGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Maintenance apply for FABJRCH3 terminated with RC04 and get
    IEW2454W message.
       When you run HPIC in IMS V13 environment after applying
    maintenance, job get ABEND S0C1 ( ABEND0C1 ) .
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for z/OS *
    *                 Version 4 Release 2 users ( FMID=H1J0420 )   *
    ****************************************************************
    * PROBLEM DESCRIPTION: When running APPLY process for PTF      *
    *                      UI24051 ( APAR PI27561 ) of IMS HP      *
    *                      Image Copy maintenance, IEW2454W        *
    *                      ( MSGIEW2454W ) is issued at the        *
    *                      link-edit process of the object module  *
    *                      FABJRCH3 in the load module FABJMAIN.   *
    *                      And IMS HP Image Copy terminates with   *
    *                      ABEND S0C1 ( ABEND0C1 ) if you run it   *
    *                      in IMS V13 environment with the SMP/E   *
    *                      target library as the runtime library.  *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When running APPLY process for PTF UI24051 ( APAR PI27561 ) of
    IMS HP Image Copy maintenance, IEW2454W ( MSGIEW2454W ) is
    issued at the link-edit process of the object module FABJRCH3 in
    the load module FABJMAIN. And IMS HP Image Copy terminates with
    ABEND S0C1 ( ABEND0C1 ) if you run it in IMS V13 environment
    with the SMP/E target library as the runtime library.
    The CSECT name of object module FABJRCH3 has been changed to
    FABJRCH4 from FABJRCH3, and CSECT name is duplicate with the
    object module FABJRCH4. Therefore FABJRCH3 entry in FABJMAIN
    program is unresolved and IMS HP Image Copy can not fetch the
    FABJRCH3 at running time.
    

Problem conclusion

  • The CSECT name of FABJRCH3 is brought back to FABJRCH3.
    
    Following modules have been re-assembled:
      FABJRCHA FABJRCHB FABJRCH2 FABJRCH3 FABJRCH4 FABJRCH9
    

Temporary fix

  • *********
    * HIPER *
    *********
    

Comments

APAR Information

  • APAR number

    PI36446

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-03-06

  • Closed date

    2015-03-12

  • Last modified date

    2015-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI25858

Modules/Macros

  • FABJRCHA FABJRCHB FABJRCH2 FABJRCH3 FABJRCH4
    FABJRCH9
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI25858

       UP15/03/13 P F503 «

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"4.2.0","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 July 2020