IBM Support

PI33571: STORED PROCEDURE CALL FAILS WITH BIGINT PARAMETERS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • On z/OS, a message flow that calls a DB2 stored procedure with a
    parameter of data type BIGINT might fail with the following
    error:
    
    BIP2322E DATABASE ERROR: SQL STATE '22003';
    NATIVE ERROR CODE '-99999';
    ERROR TEXT '{DB2 FOR OS/390}{ODBC DRIVER} SQLSTATE=22003
    ERRLOC=2:70:2'
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of WebSphere Message Broker V8.0 and IBM Integration
    Bus V9.0 on z/OS using DB2 stored procedures via ODBC.
    
    
    Platforms affected:
    z/OS
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    On z/OS, a message flow that calls a DB2 stored procedure over
    an ODBC connection with a
    parameter of data type BIGINT might fail with the following
    error:
    
    BIP2322E DATABASE ERROR: SQL STATE '22003';
    NATIVE ERROR CODE '-99999';
    ERROR TEXT '{DB2 FOR OS/390}{ODBC DRIVER} SQLSTATE=22003
    ERRLOC=2:70:2'
    
    This is due to the product binding the value to the BIGINT
    parameter using the wrong C Data type.
    
    There are a number of resource name changes between WebSphere
    Message Broker and IBM Integration Bus Version 9.0. For details
    visit
    http://pic.dhe.ibm.com/infocenter/wmbhelp/v9r0m0/topic/com.ibm.e
    tools.mft.doc/bb23814_.htm
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI33571

  • Reported component name

    IB Z/OS

  • Reported component ID

    5655IBB00

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-27

  • Closed date

    2015-02-26

  • Last modified date

    2015-04-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IB Z/OS

  • Fixed component ID

    5655IBB00

Applicable component levels

  • R900 PSY

       UP