Error description

  • In z/OS 2.1 or later, ABENDS0C4-4 at IDA019L1+2B7E during the
    VSAM POINT macro if two or more DBPCBs are used as HSSRPCB and
    one gets status code GB in a user application using HP Unload
    API.  The length of the VSAM PLH header was changed in z/OS 2.1.
    keyword:  ZOS0201T/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM IMS High Performance Unload *
    *                 for z/OS Version 1 Release 2 (FMID=H1IN120). *
    ****************************************************************
    * PROBLEM DESCRIPTION: In z/OS 2.1, ABENDS0C4-4 at IDA019L1    *
    *                      +2B7E (IDA019R1+2746) during the VSAM   *
    *                      POINT macro if two or more DBPCBs are   *
    *                      used as HSSRPCB and one gets status     *
    *                      code GB in a user application using     *
    *                      HP Unload API.                          *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR fixes the problem described in the Problem Description
    field.
    

Problem conclusion

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IBM IMS High Performance Unload for z/OS User's Guide
    Version 1 Release 2 Suffix 7 (SC27-0936-07) should be changed
    as follows:
    ---------------------------------------------------------------
    7.2     Messages and codes
    7.2.4   Messages
    7.2.4.1 FABH messages
    --------------------------------------------------------------
    | FABH0592E UNACCEPTABLE VSAM LOGICAL ERROR (RPLREQ=xx,
    |           RPLFDBWD=xxxxxxxx)
      Explanation: HSSR buffer handler has encountered an
      unexpected VSAM logical error during processing of while
    | it was processing VSAM ESDS data sets. RPLREQ shows the
    | VSAM macro function that was invoked, and RPLFDBWD shows
    | VSAM feedback information related to VSAM failure. These
    | values are shown in hexadecimal.
    | System Action: HSSR Engine ends abnormally.
    | User response: This error is likely an internal system error.
    | Contact IBM Software Support.
    --------------------------------------------------------------
    ================= End of Documentation Change ==================
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI33550

  • Reported component name

    IMS HIGHPERF UN

  • Reported component ID

    5655E0600

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-01-27

  • Closed date

    2015-02-03

  • Last modified date

    2015-04-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI24925

Modules/Macros

  •    FABHA20  FABH511
    

Publications Referenced
SC27093607    

Fix information

  • Fixed component name

    IMS HIGHPERF UN

  • Fixed component ID

    5655E0600

Applicable component levels

  • R120 PSY UI24925

       UP15/02/05 P F502

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.