IBM Support

PI31859: ABENDS OCCUR WHEN STOPPING AND RESTARTING A PE SERVER SUBTASK

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • During a shutdown and restart of OMPE an ABEND23E in FPEVDB2I
    followed by an ABEND0C4 in D5DCON.
    Issueing a stop,  F STCname,F PESERVER,P ssid
    followed by start F STCname,F PESERVER,S ssid
    without waiting for the stop to complete results in several
    abends and ultimatetly an 0C4 in D5DCON.
    A selection of messages during this abend series
    CI0760: PROCESSING COMMAND
    CI0720: PROCESS MESSAGES FOLLOW
    FPEV0165I  MSTR INSTANCE FOR DB2 SUBSYSTEM DSNT IS STOPPING
    FPEV0059E  DSNT DB2 INTERFACE TASK DID NOT RESPOND TO
      TERMINATION REQUEST
    CI0970: OMEGAMON SUBTASK ABEND CODE=04000000
     PSW=078D1000B6241076  TCB=008B4B00
    CI0971: PROGRAM NAME=FPEVDB2I
    FPEV0062E  DSNT HISTORY MANAGER TASK DID NOT RESPOND TO
    TERMINATION REQUEST
    FPEV0851I  DSNT DATA MANAGER MAIN TASK ENDED
    An ABEND23E occurs
    

Local fix

  • Wait for
    FPEV0224I  MSTR INSTANCE FOR DB2 SUBSYSTEM subsytstem STOPPED
    before issuing start command
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: Abends with system completion code 23E  *
    *                      or 0C4 occur when stopping and          *
    *                      restarting a monitoring PE Server       *
    *                      subtask.                                *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    PROBLEM SUMMARY:
    When the OMEGAMON Collector is up and running and the modify
    command is used to stop a dedicated monitoring PE Server
    subtask, a subsequent start command for the same PE Server
    subtask will cause Abends if the start command is issued before
    the monitoring PE Server ends.
    
    PROBLEM CONCLUSION:
    The code has been corrected accordingly. The start command is
    ignored until the currently monitoring PE Server subtask has
    completed termination processing.
    
    KEYWORDS:
    ABEND 23E 0C4 RESTART
    
    CIRCUMVENTION:
    When stopping a monitoring PE Server subtask, wait for the
    completion message FPEV0224I before starting the PE Server
    subtask again.
    

Problem conclusion

  • The code has been corrected accordingly. The start command is
    ignored until the currently monitoring PE Server subtask has
    completed termination processing.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI31859

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-12-19

  • Closed date

    2015-03-11

  • Last modified date

    2017-02-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI25822 UI25823

Modules/Macros

  •    DGOVMSTR
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI25822

       UP15/03/12 P F503

  • R520 PSY UI25823

       UP15/03/12 P F503

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 May 2020