A fix is available
APAR status
Closed as program error.
Error description
During a shutdown and restart of OMPE an ABEND23E in FPEVDB2I followed by an ABEND0C4 in D5DCON. Issueing a stop, F STCname,F PESERVER,P ssid followed by start F STCname,F PESERVER,S ssid without waiting for the stop to complete results in several abends and ultimatetly an 0C4 in D5DCON. A selection of messages during this abend series CI0760: PROCESSING COMMAND CI0720: PROCESS MESSAGES FOLLOW FPEV0165I MSTR INSTANCE FOR DB2 SUBSYSTEM DSNT IS STOPPING FPEV0059E DSNT DB2 INTERFACE TASK DID NOT RESPOND TO TERMINATION REQUEST CI0970: OMEGAMON SUBTASK ABEND CODE=04000000 PSW=078D1000B6241076 TCB=008B4B00 CI0971: PROGRAM NAME=FPEVDB2I FPEV0062E DSNT HISTORY MANAGER TASK DID NOT RESPOND TO TERMINATION REQUEST FPEV0851I DSNT DATA MANAGER MAIN TASK ENDED An ABEND23E occurs
Local fix
Wait for FPEV0224I MSTR INSTANCE FOR DB2 SUBSYSTEM subsytstem STOPPED before issuing start command
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - PE Server subtask * **************************************************************** * PROBLEM DESCRIPTION: Abends with system completion code 23E * * or 0C4 occur when stopping and * * restarting a monitoring PE Server * * subtask. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: When the OMEGAMON Collector is up and running and the modify command is used to stop a dedicated monitoring PE Server subtask, a subsequent start command for the same PE Server subtask will cause Abends if the start command is issued before the monitoring PE Server ends. PROBLEM CONCLUSION: The code has been corrected accordingly. The start command is ignored until the currently monitoring PE Server subtask has completed termination processing. KEYWORDS: ABEND 23E 0C4 RESTART CIRCUMVENTION: When stopping a monitoring PE Server subtask, wait for the completion message FPEV0224I before starting the PE Server subtask again.
Problem conclusion
The code has been corrected accordingly. The start command is ignored until the currently monitoring PE Server subtask has completed termination processing.
Temporary fix
Comments
APAR Information
APAR number
PI31859
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
511
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-12-19
Closed date
2015-03-11
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI25822 UI25823
Modules/Macros
DGOVMSTR
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 May 2020