Error description
Data Studio/OQWT, OPTKEY SCHEMA is a parameter in the CQMPARMS parameter file but is not in the monitoring profile. If the SCHEMA OPTKEY is coded in CQMPARMS and Override OPTKEYS "Y" is coded in the monitoring profile, SCHEMA information stops being collected. . When the SCHEMA OPTKEY is coded in CQMPARMS, this parameter will remain in effect independently of the Override OPTKEYS value in the monitoring profile.
Local fix
If the SCHEMA OPTKEY is coded in CQMPARMS and Override OPTKEYS "N" is coded in the monitoring profile, SCHEMA information will be collected.
Problem summary
**************************************************************** * USERS AFFECTED: Users of DB2 Query Monitor. * **************************************************************** * PROBLEM DESCRIPTION: Data Studio/OQWT, OPTKEY SCHEMA is a * * parameter in the CQMPARMS parameter * * file but is not in the monitoring * * profile. If the SCHEMA OPTKEY is coded * * in CQMPARMS and Override OPTKEYS "Y" * * is coded in the monitoring profile, * * SCHEMA information stops being * * collected. When the SCHEMA OPTKEY is * * coded in CQMPARMS, this parameter will * * remain in effect independently of the * * Override OPTKEYS value in * * the monitoring profile. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PI31411
Reported component name
DB2 QUERY MONIT
Reported component ID
5655E6701
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-12-11
Closed date
2015-01-30
Last modified date
2015-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI24842 UI24843
Modules/Macros
CQMMCMOX
Fix information
Fixed component name
DB2 QUERY MONIT
Fixed component ID
5655E6701
Applicable component levels
Fix is available