IBM Support

PI31338: ADVANCED ACBGEN CHANGES THE TIMESTAMP IN ACBCATWK DATA SET AS SAME AS IMS APAR PI27237.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR provides the Advanced ACBGEN utility to change the
    timestamp in ACBCATWK data set the same as the timestamp changed
     by IMS APAR PI27237.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IMS Library Integrity Utilities for z/OS,    *
    *                 Version 2 Release 2 (FMID=H27P220) users     *
    *                 who use the Advanced ACBGEN utility with     *
    *                 ACBCATWK DD specified or Catalog Manager     *
    *                 utility.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: The time stamp that is used by IMS      *
    *                      Catalog Populate utility (DFS3PU00)     *
    *                      for a PSB that has a mixture of GSAM    *
    *                      and Full Function databases is          *
    *                      incorrect when IMS Catalog Populate     *
    *                      utility uses the ACBCATWK data set      *
    *                      which was generated by Advanced ACBGEN  *
    *                      utility.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Advanced ACBGEN utility with IMS V12 or later is fixed to
    resolve the same problem reported by IMS V13 APAR PI27237.
    
    The specification of ACBCATWK data set was changed by IMS APAR
    PI27237. The new specification solves the problem that the time
    stamp is incorrect when IMS Catalog Populate utility (DFS3PU00)
    uses the ACBCATWK data set to populate an IMS catalog.
    The problem occurs only for PSB that has a mixture of GSAM and
    Full Function databases.
    
    Advanced ACBGEN utility provides ACBCATWK data set with the new
    specification for the IMS version 12 or later.
    The time stamp stored in ACBCATWK data set includes the year,
    day and the time of the day instead of only the time of the
    day.
    
    The restriction of Catalog Manager utility is changed for the
    fix and the documentation is updated.
    

Problem conclusion

  • The following module has been changed to fix the above problem:
     - FABQMAIN
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The documentation " IMS Library Integrity Utilities for
    z/OS, V2R2, User's Guide (SC19-3979-01)" is changed as follows.
    ================================================================
    Chapter 9. Catalog Manager utility
     Catalog Manager utility restrictions
    :
     - The Catalog Manager utility checks only DBDs and PSBs that
       are found in the ACB libraries. DBDs and PSBs that are found
       in the IMS catalog but not in the ACB libraries are not
       checked or included in the IMS Catalog Validation report.
    |- Depending on the maintenance level of IMS, the Catalog
    |  Manager utility cannot validate PSBs that contain PCBs
    |  referring to a GSAM or a logical database. This is because no
    |  time stamp information is stored for such PSBs in the IMS
    |  catalog. To validate such PSBs generated by IMS Version 13,
    |  you must apply APAR PI27237 to IMS.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI31338

  • Reported component name

    IMS LIBR INTEG

  • Reported component ID

    5655I4200

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-12-10

  • Closed date

    2015-01-23

  • Last modified date

    2015-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI24605

Modules/Macros

  •    FABQMAIN
    

Publications Referenced
SC19397901    

Fix information

  • Fixed component name

    IMS LIBR INTEG

  • Fixed component ID

    5655I4200

Applicable component levels

  • R220 PSY UI24605

       UP15/01/26 P F501

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220"}]

Document Information

Modified date:
03 October 2020