IBM Support

PI29813: IOS APPLICATIONS WITH MULTIPLE DATA MODELS CRASH AFTER UPDATE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Will get an error in Xcode when trying to connect to Worklight
    using the iOS native API:
    [ERROR] Worklight: +[WLCookieManager
    persistentStoreCoordinator]:326::Unresolved error
    This happens when trying to call this line:
    [[WLClient sharedInstance]
    wlConnectWithDelegate:connectListener];
    It was working fine and able to connect to the Worklight server
    without any issue, but now it keeps throwing this error. The
    only change made was to try and show a dialog from the
    application. After reverting this change the error still
    exists.
    Affects WL6.1 users, hybrid and native iOS apps.
    

Local fix

  • Un-install the application on the device and then install the
    update fresh
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users who add another coredata model to wl app               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Worklight coredata would not migrate well if another         *
    * coredata model is present from the client - app will crash   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * -                                                            *
    ****************************************************************
    

Problem conclusion

  • Crashing if fixed, wl does not try to catch all models and
    converge them
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI29813

  • Reported component name

    WL/MFPF ENTERPR

  • Reported component ID

    5725I4300

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-11-18

  • Closed date

    2014-11-23

  • Last modified date

    2014-11-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WL/MFPF ENTERPR

  • Fixed component ID

    5725I4300

Applicable component levels

  • R600 PSY

       UP

  • R610 PSY

       UP