IBM Support

PI28815: U3000/SA03 ABEND RUNNING OPTIMZ IN BATCH

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Optim/z batch terminates with a U3000 abend followed by a SA03.
    

Local fix

  • Increase CPU limit for job step.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Optim/z users running Optim/z in batch with POSIX ON.        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Optim/z batch terminates with a U3000 abend followed by a    *
    * SA03.                                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply the provided fix.                                      *
    ****************************************************************
    When the job exceeds the zOS CPU limit without POSIX ON it will
    terminate with a S322 abend.  When POSIX is ON, a SIGXCPU signal
    is raised instead.  If the program does not handle this signal
    LE will terminate with U3000.  This does not make the problem
    clear to the user.
    

Problem conclusion

  • Optimz now handles this signal and issues a system error report
    "Execution terminated by system due to CPU usage limit".
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI28815

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-31

  • Closed date

    2014-11-17

  • Last modified date

    2014-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI28816

Modules/Macros

  • fopmmain fopcinit fopcfpmn fophsm
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • R720 PSY UI23143

       UP14/11/19 P F411

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.