IBM Support

PI27636: SUPPORT FOR IMS V14

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Support for IMS V14
    KEYWORDS: IMSV14TGT/K IMSV13TGT/K
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS High Performance Unload for *
    *                 z/OS Version 1 Release 2 (FMID=H1IN120)      *
    ****************************************************************
    * PROBLEM DESCRIPTION: This APAR provides the following new    *
    *                      capabilities of HP Unload:              *
    *                      1. Run under IMS Version 14             *
    *                      2. Unload HALDB 8GB OSAM data sets      *
    *                         in IMS V13 and V14                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR enables HP Unload to support IMS Version 14.
    
    And HALDB OSAM 8GB data sets are supported as input.
    If a HALDB to be unloaded is registered as OSAM8G in the RECON
    data set, the FABH0399I WTO message is issued:
     FABH0399I HALDB dbdname IS DEFINED AS OSAM8G
    

Problem conclusion

Temporary fix

Comments

  • ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IBM IMS High Performance Unload for z/OS User's Guide
    Version 1 Release 2 Suffix 7 (SC27-0936-07) should be changed
    as follows:
    ---------------------------------------------------------------
     3.6  System programming interfaces
     3.6.4 User record-formatting routine
     3.6.4.3 Call parameters
    
     Parameter 7: RBA of segment prefix
    
      This 4-byte field contains the relative byte address of
      the segment prefix. The content of this field has
      a meaning only for HD databases. The user routine must never
      modify this field.
    
      If your IMS environment supports an OSAM database larger
      than 4 gigabytes, be careful with the RBA. You must check
      the flag byte SPRBAFLG when you treat an RBA.
      The flag SPRBAX4G in this flag byte is on if and only
      if all of the following conditions are satisfied:
    | - Your IMS environment supports relative byte addressability
    |   for up to 8 gigabytes of data in an OSAM, HDAM, HIDAM,
    |   PHDAM, or PHIDAM database data set.
      - Your database is an OSAM database.
      - Your database has an even block size.
      - The RBA of the segment prefix is larger than or equal
        to 4 gigabytes.
    
      Thus, if your IMS environment satisfies the first condition,
      you must check whether the flag SPRBAX4G is on or off.
      If the flag is on, the value in SPRBA is not the real RBA.
      In this case, you must move bit 1 of SPRBA to bit position 33
      to get the real 33-bit RBA. See the sample code provided
      in the following figure.
    ---------------------------------------------------------------
    7.2     Messages and codes
    7.2.4   Messages
    7.2.4.1 FABH messages
    --------------------------------------------------------------
     FABH0031E DDNAME=ddname; DATA REQUEST OUTSIDE OF DATA SET
               LIMITS
    
      Explanation: The CAB buffer handler has received a data
      request for an OSAM block number or ESDS CI number that is
      not within the extents of the data set (indicated by
      ddname).
      System Action: HSSR Engine ends abnormally.
      User Response: Complete the following tasks to identify
      the cause, and take appropriate actions:
      - Activate the compare and hardcopy trace options, and
        execute the failing call sequence with the FABHTEST
        utility
       (see "FABHTEST utility for problem determination" in topic
       7.1.3).
      - Ensure that the database processed by HSSR Engine was not
        being updated at the time when the error occurred.
    | - If an OSAM block over 4 gigabytes is requested by an odd
    |   RBA in the HALDB, ensure that the HALDB is defined as
    |   OSAM8G in the RECON data sets.
    --------------------------------------------------------------
    | FABH0399I HALDB dbdname IS DEFINED AS OSAM8G
    |
    | Explanation:  The indicated HALDB is defined as OSAM8G
    | in the RECON data set and the maximum capacity of OSAM data
    | sets is 8 gigabytes of data.
    | System Action:  HSSR Engine continues processing.
    | User Response:  None
    --------------------------------------------------------------
    ================= End of Documentation Change ==================
    

APAR Information

  • APAR number

    PI27636

  • Reported component name

    IMS HIGHPERF UN

  • Reported component ID

    5655E0600

  • Reported release

    120

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / New Function / Xsystem

  • Submitted date

    2014-10-14

  • Closed date

    2014-12-15

  • Last modified date

    2015-05-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI23871

Modules/Macros

  •    FABHA01  FABHA30  FABHB20  FABHB30  FABHC00
    FABHDATE FABHFCKR FABHFPH4 FABHFSU  FABHFSU4 FABHGDL4 FABHHSSR
    FABHHTBL FABHJCB  FABHJCB0 FABHKEYX FABHLINK FABHPSL4 FABHRPTH
    FABHRTI0 FABHTCBU FABHTEST FABHTES4 FABHURG1 FABHURG3 FABHURG4
    FABHX034 FABH001  FABH002  FABH0034 FABH0104 FABH011  FABH015
    FABH015A FABH0203 FABH0204 FABH021  FABH022  FABH0304 FABH031
    FABH040  FABH041  FABH0424 FABH050  FABH060  FABH070  FABH080
    FABH081  FABH082  FABH083  FABH090  FABH091  FABH092  FABH093
    FABH100  FABH105  FABH110  FABH111  FABH120A FABH120B FABH1202
    FABH1203 FABH1204 FABH1208 FABH1209 FABH130  FABH140  FABH150
    FABH160  FABH190  FABH2004 FABH201  FABH2504 FABH500  FABH510
    FABH511  FABH512  FABH513  FABH5154 FABH5164 FABH520  FABH530
    FABH535  FABH5404 FABH550  FABH560  FABH620  FABH6304 FABH650
    FABH660  FABH661  FABH662  FABH663  FABH665  FABH680  FABH681
    FABIHTBL FABIUNLS FABIUNL4 HPSSHDRH HPSSMSGT HPSSSCAN HPSSSCA4
    HPSSSEH4 HPSUGVT0 HPSUHPTI HPSUHTBL HPSUMSGS HPSURPTH HPSURR05
    HPSURR13 HPSUURG1 HPSUURG4 HPSUUSHF H1IN120J
    

Publications Referenced
SC27093607    

Fix information

  • Fixed component name

    IMS HIGHPERF UN

  • Fixed component ID

    5655E0600

Applicable component levels

  • R120 PSY UI23871

       UP14/12/17 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSCX89K","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]

Document Information

Modified date:
14 December 2020