A fix is available
APAR status
Closed as program error.
Error description
When the print log map utility is run ( CSQJU004 ) the output returned does not include expected content. The first problem is missing date and time information within the header of the ARCHIVE LOG COMMAND HISTORY section. The second problem is the missing values in the date and time columns for each ARCHIVE LOG COMMAND. . The date and time in the header of the archive log command history section is missing because the TIME control block is not initialized in its entirety by CSQJU104 before calling CSQRJTCV to format the current time. If the fNullChk flag is on residually in the TIME block then CSQRJTCV does not format the current time and produces the result described above. This is similar to PI09112 and PI25383, however a different module is affected. . Regarding the missing values in the date and time columns for the archive log commands, this is due to the fact that the time when the archive log command was issued has not been stored in the BSDS. ALHRSTCK is set from LMB7STCK when a new archive log entry is created, but LMB7STCK is not being set when the ARCHIVE LOG command is accepted.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: When viewing the output of the print * * log map utility (CSQJU004), the time * * and date in the headers of the restart * * control, checkpoint queue or archive * * log command history sections is not * * displayed. Also, the time and date * * when the archive log commands were * * issued is not displayed. * **************************************************************** * RECOMMENDATION: * **************************************************************** When formatting the current time and date for the archive log command history section header, CSQJU104 does not correctly initialize the structure used to store the current time. Similarly, CSQJUPCR does not correctly initialize the same structure when formatting the current time and date for the restart control and checkpoint queue section headers. Also, when processing an ARCHIVE LOG command, the time when the command was accepted is not stored in the BSDS as the current time is not captured when processing the command.
Problem conclusion
CSQJU104 and CSQJUPCR are changed to properly initialize the structure used to format the current time. CSQJC05A is changed to store the time that the archive log command was accepted. 100Y CSQJC05A CSQJUPCR CSQJU104
Temporary fix
Comments
APAR Information
APAR number
PI27618
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-10-14
Closed date
2014-10-27
Last modified date
2014-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
PI27913 UI22503
Modules/Macros
CSQJC05A CSQJUPCR CSQJU104
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R100 PSY UI22503
UP14/11/13 P F411
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.