IBM Support

PI27511: WMQ 710 FOR SMF RECORDS THE FLAG WTASAEOT IS USED INTERNALLY TO INDICATE THAT MQ WILL WRITE CLASS 3 ACCOUNTING RECORDS AT EOT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR investigates externalizing WTASAEOT
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Users cannot detect when the last SMF   *
    *                      116 class 3 accounting (i.e. subtype 1) *
    *                      record is written for a long running    *
    *                      task.                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When a task is present during multiple statistic intervals,
    several WTAS blocks can be written out with information gathered
    during each interval.
    There is no indication in the SMF 116 record that the task has
    completed and no further information will be written for it.
    

Problem conclusion

  • The WTASFLAG word was added, along with the WTASAEOT flag that
    allows users to check if the task is completed. The WTASAEOT
    flag will only be set in the last SMF 116 record written for
    that task.
    100Y
    CSQDSMFC
    CSQDWTAS
    CSQ7PLRT
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI27511

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-10-13

  • Closed date

    2014-10-27

  • Last modified date

    2014-12-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PI27817 UI22505

Modules/Macros

  • CSQDSMFC CSQDWTAS CSQ7PLRT
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UI22505

       UP14/11/13 P F411

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 December 2014